SECTION 13 − TEACH POINTS

13-1. Teach Using 15 Points

Apk = Peak Amperage

Vpk = Peak Voltage

Abk = Background Amperage

PPS = Pulses Per Second

IPM / MPM

PWms = Pulse Width (Milliseconds)

 

780 / 19.8

750 / 19.1

700 / 17.8

650 / 16.5

600 / 15.2

550 / 14.0

500 / 12.7

450 / 11.4

 

 

Example Of A Synergic

400 / 10.2

Setting For 425 IPM With

 

All Teach Points Set At 50

350 / 8.9

IPM (1.3 MPM) Increments

 

300

/ 7.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

250

/ 6.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200

/ 5.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

/ 3.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

/ 2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50

/ 1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Apk

100

180

210

240

270

300

330

360

370

420

450

480

510

540

565

Apk

Vpk

10

18

21

24

27

30

33

36

37

42

45

48

51

54

56

Vpk

Abk

10

20

30

40

50

60

70

80

90

100

110

120

130

140

200

Abk

PPS

20

55

80

105

130

160

185

210

235

260

290

315

340

365

400

PPS

PWms

1

 

 

 

2

 

 

3

 

 

4

 

 

 

5

PWms

The teach mode allows the user to create custom pulse programs. The teach mode selection for 15 teach points gives a more defined curve for a specific range. At each teach point, the user can adjust five parame- ters to shape the pulse waveform of the weld output. The six parameters are: IPM (MPM), Apk, Vpk, Abk, PPS, and PWms.

Apk, Vpk, Abk, PPS, and PWms acting together provide the energy necessary to burn off welding wire at a set wire feed speed. The graph below shows that as wire feed speed increases, energy increases (Apk, Vpk, Abk, PPS, and PWms acting syn- ergically).

Under some conditions, the wire feeder lim- its wire feed speed to maintain all pulse pa- rameters within the capability of the system.

OM-1588 Page 33

Page 37
Image 37
Miller Electric DS-64M Swingarc manual Teach Points, Teach Using 15 Points