7.7Overload Protection
YStop engine. If checking fuse, disconnect battery negative (−) cable.
.Press button to reset circuit
breaker. If fuse or breaker continues to open, contact Factory Authorized Service Agent.
Weld And Auxiliary Power Circuits
1 Fuse F2
F2 protects battery excitation circuit. If F2 opens, weld and auxil- iary output stops.
2 Fuse F3
F3 protects generator excitation circuit. If F3 opens, weld and auxil- iary power output is low.
Replace any open fuses. Reinstall panel before operating unit.
Remote Control Circuit
Ref.
3
4
3 Circuit Breaker CB5
CB5 protects 24 volt ac output to Remote 14 receptacle RC1. If CB5 opens, RC1 24 volt output stops.
Engine Control Circuit
4Circuit Breakers CB6, CB7, CB8, And CB9
CB6 protects fuel solenoid circuit. If CB6 opens, the engine does not start.
CB7 protects throttle solenoid circuit. If CB7 opens, the engine does not run at weld/power speed.
CB8 protects Engine Control switch and wiring harness. If CB8 opens, the engine does not crank.
CB9
CB8
CB7
CB6
2
1
CB9 protects optional glow plug system. If CB9 opens, the glow plug does not work.
Tools Needed:
3/8 in
29 |