11.2 (Continued)
. Hardware is common and | 6 |
| |
not available unless listed. |
|
4
1
2
3
5
8
7
9
|
| 28 | 5 |
|
|
| 27 |
| 10 |
24 | 25 | 26 |
| |
|
| |||
23 |
|
| 12 | 11 |
|
|
|
| |
22 |
|
|
|
|
|
|
| 13 |
|
16
17
18 15
21 | 20 | 19 | 14 |
Item | Dia. | Part | Description | Quantity |
No. | Mkgs. | No. | ||
. . . 13 . . . . | CB5 | . . . . . 083 432 | . . CIRCUIT BREAKER, man reset 1P 10A 250VAC | . . . 1 |
. . . 14 . . . . | . . . . . . | . . . . . 039 046 | . . TERMINAL, pwr output black | . . . 1 |
. . . 15 . . . . | . . . . . . | . . . . . 170 391 | . . CONNECTOR, circ protective cap size 20 | . . . 1 |
. . . 16 . . . . | . . . . . . | . . . . . 021 385 | . . BOOT, tgl switch lever | . . . 3 |
. . . 17 . . . . | . . . . . . | . . . . . 082 788 | . . HOLDER, light ind | . . . 1 |
. . . 18 . . . . | . PL1 | . . . . *048 155 | . . BULB, incand min 14V | . . . 1 |
. . . 19 . . . . | . . . . . . | . . . . . 082 789 | . . LENS, light ind red | . . . 1 |
. . . 20 . . . . | . FG . | . . . . . 118 066 | . . GAUGE, fuel elec 12V | . . . 1 |
. . . 21 . . . . | . . . . . . | . . . ♦148 956 | . . HANDLE, switch | . . . 1 |
. . . 22 . . . . | . . . . . . | . . . . . 097 924 | . . KNOB, pointer | . . . 1 |
. . . 23 . . . . | . . . . . . | . . . . . 072 590 | . . LOCK, shaft pot | . . . 2 |
. . . 24 . . . . | . . . . . . | . . . . . 097 922 | . . KNOB, pointer | . . . 1 |
. . . 25 . . . . | . . . . . . | . . . . . 119 014 | . . LEVER, switch black | . . . 1 |
. . . 26 . . . . | . . . . . . | . . . . . . . . . . . . . . | . . NAMEPLATE, (order by model and serial number) | . . . 1 |
. . . 27 . . . . | . HM . | . . . . . 145 247 | . . METER, hour | . . . 1 |
. . . 28 . . . . | . . . . . . | . . . . 039 047 | . . TERMINAL, pwr output red | . . . 1 |
. . . . . . . . . . | . . . . . . | ♦♦♦185 190 | . . METER, amp dc 0−400 | . . . 1 |
. . . . . . . . . . | . . . . . . | ♦♦♦164 876 | . . METER, volt dc 0−100 | . . . 1 |
♦Optional 042 924 Polarity Switch.
♦♦Optional 043 253 Receptacle Kit, 120/250V 50A twk. *Recommended Spare Parts.
♦♦♦Optional 042 927 Meter Kit, volt and amp.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.