4.6Remote 14 Receptacle RC1 Information

Ref. ST-158 93

A K

J I

B

 

 

C

L N

H

D

M

G

 

E

F

*The remaining sockets are not used.

 

Socket*

Socket Information

 

A

24 volt ac with respect to socket G. Protected by circuit

 

 

breaker CB5.

 

B

Contact closure to A completes 24 volt ac contactor

 

 

control circuit.

 

G

Circuit common for 24 volt ac circuit.

 

C

0 to +10 volts dc output to remote control with respect

 

 

to socket D.

A

D

Remote control circuit common.

E

0 to +10 volts dc input command signal from remote

 

 

control with respect to socket D.

 

K

Chassis common.

20

OM-402

Page 24
Image 24
Miller Electric Metro 250D manual Remote 14 Receptacle RC1 Information, Ref. ST-158, Socket Information