3.6AC Auxiliary Power Curve

The auxiliary power curve shows the auxiliary power in amperes available at the receptacles.

SA-180 260

4.Installation

4.1Installing Welding Generator

install1 1/97 − Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854

1Generator Base

2Metal Vehicle Frame

3Equipment Grounding Terminal

4Grounding Cable

Use #10 AWG or larger insulated copper wire.

YIf unit does not have GFCI re- ceptacles, use GFCI- protected extension cord.

Movement

 

Airflow Clearance

 

Y Do not lift unit from end.

18 in

 

 

 

(460 mm)

18 in

 

 

 

 

 

18 in

(460 mm)

 

OR

(460 mm)

 

 

 

 

 

 

18 in

18 in

 

 

(460 mm)

 

 

(460 mm)

 

 

 

Location

Grounding

 

 

 

 

1

3

 

 

4

 

 

GND/PE

 

 

 

 

OR

OR

 

 

 

 

 

 

Electrically bond genera-

 

 

 

tor frame to vehicle frame

 

 

2

by metal-to-metal contact.

2

OM-402

17