Miller Electric XMS 4000 manual Operation, Front Panel Controls

Models: XMS 4000

1 40
Download 40 pages 734 b
Page 19
Image 19

SECTION 4 − OPERATION

4-1. Front Panel Controls

9

12

10

11

13

8

14

18

17

16

6

7

2

1

5

3

15

19

20

4

1ON/OFF Switch (I/O) Use switch to turn unit On/Off.

.Fan is thermostatically controlled and

runs only when necessary (Fan On Demand).

.Water cooling is automatically con-

trolled and runs only when necessary. (Cooling On Demand).

2Positive Power Connection for TIG and Stick Welding.

Do not use for MIG welding.

3Negative Power Connection for MIG, TIG and Stick Welding.

4Remote Control Receptacle for TIG and Stick welding

5Gas Connector (3/8) for TIG Welding.

6Red Quick Connect Fitting

Coolant return from torch.

7Blue Quick Connect Fitting Coolant output to torch.

8Handle

9Control Panel

10D1 (Display 1)

Displays values and parameters for se- lected welding process. During welding it shows measured welding voltage.

11 D2 (Display 2)

Displays values and parameters for se- lected welding process. During welding it shows measured welding current.

12 E1 (Encoder Control 1)

Use control to change values and parame- ters that appear on D1.

13 E2 (Encoder Control 2)

Use control to change values and parame- ters that appear on D2.

14 P1 (Memory Push Button)

Allows selecting program storage locations 1-4 as indicated by LED’s (Tig and Stick only).

15 P2 (Setup Push Button)

Allows selecting setup or advanced pro- gramming menus.

16P3 (Process Push Button) Allows selecting welding process.

17P4 (Material Push Button)

Allows selecting material type for synergic MIG and synergic pulsed MIG processes.

18 P5 (Wire Diameter Push Button)

Allows selecting desired welding wire di- ameter for synergic MIG and synergic pulsed MIG processes.

19 P6 (Gas Selection Push Button)

Allows selecting desired welding gas type for synergic MIG and synergic pulsed MIG processes.

20 P7 (Trigger Selection Push Button)

Allows selecting desired trigger mode in TIG welding and switch ON/OFF power in STICK welding.

OM-224 043 Page 15

Page 19
Image 19
Miller Electric XMS 4000 manual Operation, Front Panel Controls