page 10
ASSEMBLING THE SPRAY WAND
See Figure 5.
1. Place the threaded end of the wand extension in the
connector on the end of the spray wand assembly.
2. Turn the connector clockwise until it stops. This
secures the wand extension in place.
3. When not in use, remove the spray wand extension
from the spray wand by turning the connector
counterclockwise. Store the unassembled spray
wand in the spray wand storage holster.
ATTACHING INJECTION HOSE
See Figure 7.
Before detergent can be used with this machine, the
injection hose must be attached.
1. Remove the clear injection hose. Uncoil the hose.
2. Push the open end of the injection hose securely
over the fitting.
3. Place the filtered end of the injection hose in the
bottle of detergent.
Fig. 5
SPRAY
WAND
EXTENSION
SPRAY
WAND
GROOVED
GRIPPING
SURFACE
INJECTION
HOSE
FITTING
QUICK-CONNECT
COLLAR
HIGH
PRESSURE
HOSE
INLET
COUPLER
CONNECTING THE HIGH PRESSURE HOSE TO THE SPRAY WAND
See Figure 6.
1. Remove the high pressure hose from the storage bag
and uncoil the hose.
2. Pull back and hold the quick-connect collar on the
high pressure hose. Insert the inlet coupler on the
spray wand handle into the collar.�
3. Release the collar and push until it clicks.� Pull on
the hose to be certain it is properly secured.
Fig. 6
Fig. 7
ASSEMBLY
INJECTION
HOSE
CONNECTOR
WARNING
LISTEN FOR A “CLICK” THEN PULL ON HOSE TO BE
CERTAIN IT IS SECURELY TIGHTENED
“CLICK”
Make sure the nozzle and hose connections are
secure before starting the machine. A non-secured
accessory could become a projectile if not properly
installed which could result in serious injury.