Recording (continued)

Setup Menu

 

 

Emergency Recording Setup

This item is used to set the emergency recording settings. When the EMERGENCY terminal is grounded by the alarm sensor while both of the MAIN switch on the rear panel and the POWER button on the front panel are turned ON, emergency recording starts automatically overriding all the other settings even during timer recording or the unit is in stop mode.

Emergency recording is not performed while the MAIN switch or POWER button is turned OFF or while timer recording stand-by mode.

The setting of the <Recording> menu cannot be changed during normal recording or alarm recording. To change setting during recording, stop recording in case of normal recording. In case of alarm recording, when the “Alarm Input” in the <Recording> menu is set to “Off,” the alarm input is not accepted for 5 minutes. When you stop recording during this time, the setting change of the <Recording> menu is available.

Setup Menu

1 Recording

5Emergency Recording Setup

D Emergency Record Settings

[Recording]

step1. Select the frame or field recording.

step2. Set the long pre-alarm recording time in “Pre-alarm Duration.”

0min: Does not execute the long pre-alarm recording.

step3. Set the emergency recording time in “Post-alarm Duration.”

step4. Set the maximum recording rate.

[Camera Setting]

step5. Set the recording camera.

The button function changes between “All Off” and “All On” each time you select this button.

step6. Select “Execute.”

• The preview screen appears.

Emergency recording

1)The picture grade is “L6-30KB” and the recording rate is set to the value obtained by dividing the maximum emergency recording rate by the number of specified cameras.

When the LPA area is set in the main device, the emergency recording data is stored in the LPA area and is automatically locked in 512 MB unit including the emergency recording data in order to prevent overwriting the data.

In LPA area, the data is always recorded at the rate set for alarm recording regardless of an input of the emergency signal. Therefore, when the emergency recording is started from the mid-part of the data block, the data recorded before the ground of the EMERGENCY terminal is stored in the locked area along with the emergency recording.

When you set the long pre-alarm recording time without setting the LPA area, long pre-alarm recording is carried out using the internal memory for pre-alarm recording, so long pre-alarm recording is performed for the short time period regardless of the setting.

When emergency recording is carried out using the LPA area, data is not stored chronologically and alarms are listed out of sequence. Be careful when searching for the desired picture.

When power failure occurs during emergency recording,

the emergency recording is cancelled after returning from the power failure.

When emergency recording is carried out during timer

recording, the end time of the timer recording is extended until the emergency recording is completed. The timer recording is finished after completing the emergency recording.

2)Cameras to be used

Cameras which are set in <Emergency Recording Setup> are used.

3)During emergency recording:

“E-REC” is displayed on the screen in red.

The camera number buttons and camera number dis- play on the screen which are used for emergency re- cording flash.

4)Emergency recording is registered in the alarm list and displayed in magenta.

52

Page 55
Image 55
Mitsubishi Electronics DX-TL4516U instruction manual Emergency Recording Setup, Emergency recording, Camera Setting

DX-TL4516U specifications

The Mitsubishi Electronics DX-TL4516U is a cutting-edge digital video recorder (DVR) designed for security and surveillance applications. This advanced DVR excels in providing reliable video management along with comprehensive features suitable for various environments, from small businesses to larger enterprise settings.

At the heart of the DX-TL4516U is its ability to support 16-channel recording, which allows users to monitor multiple points simultaneously. The device accommodates both analog and IP cameras, making it a versatile choice for users looking to upgrade their existing systems or implement a new setup. The hybrid functionality ensures that users can maximize their investment in existing camera infrastructure while seamlessly integrating new technology.

One of the standout features of the DX-TL4516U is its high-resolution recording capability. The DVR supports video recordings at 4CIF resolution, providing clear and detailed images for critical monitoring. This clarity ensures that surveillance footage can be used effectively for identification and analysis, which is crucial in security applications.

Another key technology included in the DX-TL4516U is its built-in storage management system. With a capacity of up to 8TB through an internal hard drive, users benefit from extended recording times without needing frequent data management. The DVR's intelligent overwrite functionality automatically recycles older footage, ensuring that critical newer recordings remain accessible.

The user interface of the DX-TL4516U is designed for ease of use, featuring an intuitive menu system that simplifies navigation through settings and playback options. Remote access capabilities are also integrated, allowing users to view live feeds or recorded footage from virtually anywhere using a compatible device connected to the internet.

Multiple backup options, including USB and network protocols, provide robust data protection measures. The DX-TL4516U efficiently supports remote backup and data transfer, which is essential for businesses that require stringent data security protocols.

In terms of networking features, the device includes support for dynamic IP addresses and can be integrated into various network environments, enhancing its adaptability to different user needs and settings.

Overall, the Mitsubishi Electronics DX-TL4516U emerges as a formidable player in the DVR market, offering an exceptional blend of performance, reliability, and user-friendly features. Its robust architecture and cutting-edge technologies make it an ideal solution for effective surveillance management across diverse applications.