Recording (continued) | Setup Menu |
|
|
Emergency Recording Setup
This item is used to set the emergency recording settings. When the EMERGENCY terminal is grounded by the alarm sensor while both of the MAIN switch on the rear panel and the POWER button on the front panel are turned ON, emergency recording starts automatically overriding all the other settings even during timer recording or the unit is in stop mode.
Emergency recording is not performed while the MAIN switch or POWER button is turned OFF or while timer recording
The setting of the <Recording> menu cannot be changed during normal recording or alarm recording. To change setting during recording, stop recording in case of normal recording. In case of alarm recording, when the “Alarm Input” in the <Recording> menu is set to “Off,” the alarm input is not accepted for 5 minutes. When you stop recording during this time, the setting change of the <Recording> menu is available.
Setup Menu
1 Recording
5Emergency Recording Setup
D Emergency Record Settings
[Recording]
step1. Select the frame or field recording.
step2. Set the long
0min: Does not execute the long
step3. Set the emergency recording time in
step4. Set the maximum recording rate.
[Camera Setting]
step5. Set the recording camera.
•The button function changes between “All Off” and “All On” each time you select this button.
step6. Select “Execute.”
• The preview screen appears.
Emergency recording
1)The picture grade is
When the LPA area is set in the main device, the emergency recording data is stored in the LPA area and is automatically locked in 512 MB unit including the emergency recording data in order to prevent overwriting the data.
In LPA area, the data is always recorded at the rate set for alarm recording regardless of an input of the emergency signal. Therefore, when the emergency recording is started from the
When you set the long
When emergency recording is carried out using the LPA area, data is not stored chronologically and alarms are listed out of sequence. Be careful when searching for the desired picture.
When power failure occurs during emergency recording,
the emergency recording is cancelled after returning from the power failure.
When emergency recording is carried out during timer
recording, the end time of the timer recording is extended until the emergency recording is completed. The timer recording is finished after completing the emergency recording.
2)Cameras to be used
Cameras which are set in <Emergency Recording Setup> are used.
3)During emergency recording:
•
•The camera number buttons and camera number dis- play on the screen which are used for emergency re- cording flash.
4)Emergency recording is registered in the alarm list and displayed in magenta.