71
Operations
LAN (Communication) Setting
This item is used to make the communication settings
between this unit and the PC connected to LAN terminal.
COM/LAN1
1
3
2
3
D
step
2
step
7
step
1
step
3
step
5
step
6
step
4
D
4
System Menu
LAN (Communication) Setting
LAN Address Setting
Service Port Setting
Alarm Notification Detailed Information
E-mail Notification Information
IP Alarm Notification Information
E-mail Notification Detailed Information
[LAN Address Setting]
step1. Set the IP address, sub net mask, and Gateway.
• MAC address is shown on the bottom of the
screen of <LAN (Communication) Setting>.
Do not assign “000.000.000.000” to IP address
and broadcast address. If this address is assigned,
communications or any other functions of this unit may
not be performed correctly.
The setting cannot be changed during recording. Stop
recording before changing the setting.
[Service Port Setting]
step2. Set the port setting of “Web,” “User Access,” and

“Administrator.”

• This item is used to set the port number which is
necessary to connect with PC.
Normally, leave the setting as is.
Do not change th e setting without sufficient k nowledge
about the network setting.
When making the settings other than communication port
settings of “Web,” “ User Acce ss,” an d “Admi nistrator,”
using the supplied application software, DX-PC55U, is
required. Refer to the operation manual of the application
software.
[E-mail Notification Information]
step3. Check the settings of “E-Mail Address” and

“Recorder ID.”

• When selecting “Mail,” the e-mail is sent for the
selected address.
Using the web function of this unit is required to input
“E-Mail Address” and “Recorder ID.”
[E-mail Notification Detailed Information]
step4. Check the contents to be transmitted to the PC.
Remain: Transmits signal when the remaining
capacity reaches the value set for Call out setting.
Temp /Fa n: T ran smi ts s ign al whe n t he h igh
temperature is detected or the fan is stopped.
Reboot: Transmits signal when the unit is
rebooted.
Record: Transmits signal when the recording is
started.
Alarm: Transmits signal when the alarm recording
is started.
Sensor: Transmits signal when the signal is input
to the terminal on the rear panel.
Using the web function of this unit is required to change
the contents to be transmitted.
[IP Alarm Notification Information]
step5. Check the settings of “IP Address” and “Target Port.”
• This item is used to transmit warning signals or
signals of status change such as a closure of a
rear terminal to the PC connected.
When selecting “Test,” the sending test for the
set IP address and port is executed.
Using the supplied application software, DX-PC55U, is
required to change the IP address and target port. Refer
to the operation manual of the application software.
Trans miss ion of s igna l to bro adca st a ddre ss i s no t
supported.
[Alarm Notification Detailed Information]
step6. Check the contents to be transmitted to the PC.
Remain: Transmits signal when the remaining
capacity reaches the value set for Call out setting.
Temp /Fa n: T ran smi ts s ign al whe n t he h igh
temperature is detected or the fan is stopped.
Reboot: Transmits signal when the unit is
rebooted.
Record: Transmits signal when the recording is
started.
Alarm: Transmits signal when the alarm recording
is started.
Sensor: Transmits signal when the signal is input
to the terminal on the rear panel.
Using the supplied application software, DX-PC55U, is
required to change the contents to be transmitted. Refer
to the operation manual of the application software.
step7. Select “Return” in the screen of <LAN

(Communication) Setting>.

• When the setting of “IP Address,” “Sub Net
Mask,” “Gateway,” or “Service Port Setting” is
changed, the power turns off automatically and
then the unit restarts.