COMMUNICATION SPECIFICATIONS
5.2 Remote Register Assignment
5.2.1 Remote registers (master unit → inverter (FR-E5NC))
| Device No. | Signal | Description |
|
| RWW0 | Monitor code | Set the monitor code to be referenced. By switching on the RYC signal after setting, the |
|
| specified monitored data is set to RWr0. |
| ||
|
|
|
| |
|
|
| Specify the set frequency. At this time, whether it is written to RAM or E2PROM is |
|
| RWW1 | Set frequency | differentiated by the RYD and RYE signals. After setting the frequency to this register, switch |
|
| on the above RYD or RYE to write the frequency. On completion of frequency write, RXD or |
| ||
|
|
|
| |
|
|
| RXE switches on in response to the input command. |
|
|
|
| Set the instruction code for execution of operation mode rewrite, Pr. read/write, error |
|
| RWW2 | Instruction code | reference, error clear, etc. (refer to page 29). The corresponding instruction is executed by |
|
| switching on RYF after completion of register setting. RXF switches on on completion of |
| ||
|
|
|
| |
|
|
| instruction execution. |
|
|
|
| Set the data specified by the above instruction code. (When required) |
|
| RWW3 | Write data | Switch RYF on after setting the above instruction code and this register. |
|
|
|
| Set zero when the write code is not required. |
|
5.2.2 Remote registers (inverter |
| |||
|
|
|
|
|
|
|
|
|
|
| RWr0 | Monitored value | The monitored value specified by RWW0 (monitor code) is set. |
|
|
|
|
|
|
| RWr1 | Output frequency | The present output frequency is always set. |
|
|
|
|
|
|
| RWr2 | Reply code | The reply code corresponding to RWW2 (instruction code) is set. 0 is set for a normal reply |
|
| and a value other than 0 is set for a data error. |
| ||
|
|
|
| |
| RWr3 | Read data | For a normal reply, the reply data to the instruction specified by the instruction code is set. |
|
28