COMMUNICATION SPECIFICATIONS

 

5.3 Instruction Codes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

Code Number

Description

 

 

 

 

0000H: CC-Link operation

 

 

Operation mode read

007BH

0001H: External operation

 

 

 

 

0002H: PU operation

 

 

Operation mode write

00FBH

0000H: CC-Link operation

 

 

0001H: External operation

 

 

 

 

 

 

Alarm history No. 1, No. 2 read

0074H

Reads the most recent No. 1 and 2 alarms.

 

 

Alarm history No. 3, No. 4 read

0075H

Reads the most recent No. 3 and 4 alarms.

 

 

Alarm history No. 5, No. 6 read

0076H

Reads the most recent No. 5 and 6 alarms.

 

 

Alarm history No. 7, No. 8 read

0077H

Reads the most recent No. 7 and 8 alarms.

 

 

Set frequency (RAM) read

006DH

Reads the set frequency (RAM). (Note)

 

 

Set frequency (E2PROM) read

006EH

Reads the set frequency (E2PROM). (Note)

 

 

Set frequency (RAM) write

00EDH

Writes the set frequency to RAM. (Note)

 

 

Set frequency (E2PROM) write

00EEH

Writes the set frequency to E2PROM. (Note)

 

 

Parameter read

0000H to 006CH

Refer to the data code list in the inverter manual, and perform read/write as

 

 

Parameter write

0080H to 00ECH

required. It should be noted that some parameters cannot be accessed.

 

 

 

 

 

 

 

Batch alarm definition clear

00F4H

9696H: Batch-clears the alarm history.

 

 

 

 

9696H: Parameter clear (parameters values other than calibrated values are reset

 

 

Parameter clear

00FCH

to factory settings.)

 

 

 

 

9966H: All clear

 

 

Inverter reset

00FDH

9696H: Resets the inverter.

 

Note: Setting can be made from the remote register.