Controlling the LCD monitor via RS-232C/RS-485 Remote Control

This LCD monitor can be controlled by the computer connected by an RS-232C cable or a CAT5 cable via the supplied CAT5 Tx BOX.

Functions that can be controlled by a personal computer are:

Power ON or OFF

Switching between input signals

Connection

Connection by RS-232C (For RS-232C cable, the reverse type cable should be used.)

 

Monitor

Monitor

PC

To RS-232C IN To RS-232C OUT

To RS-232C IN To RS-232C OUT

RS-232C cable

RS-232C cable

Connection by CAT5 RS-485 (For CAT5 cable, the straight type cable should be used)

 

Type A

Type B

CAT5 Tx BOX

 

 

 

 

 

(supplied)

 

 

 

 

 

USB cable

 

Monitor

Monitor

 

 

 

 

 

 

PC

To RS-232C

To CAT5

To CAT5

To CAT5

To CAT5

To CAT5

 

IN

OUT

RGB5 IN

OUT

RGB5 IN

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAT5 cable

 

 

 

 

 

 

 

 

CAT5 cable

 

 

 

RS-232C cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This connection isn’t necessary when the USB COM port is used.

NOTE:

If your PC (IBM or IBM compatible) is equipped only with a 25-pin serial port connector, a 25-pin serial port adapter is required. Contact your dealer for details.

1) Interface

PROTOCOL

RS-232C/RS-485 (CAT5)

 

 

BAUD RATE

9600 [bps]

 

 

DATA LENGTH

8 [bits]

 

 

PARITY BIT

NONE

 

 

STOP BIT

1 [bits]

 

 

FLOW CONTROL

NONE

 

 

This LCD monitor uses RXD, TXD and GND lines for RS-232C control.

2) Control command diagram

The command is structured by the address code, function code, data code and end code. The length of the command is different for each function.

 

Address code

Function code

Data code

End code

 

HEX

30h 30h

 

Function

Data

0Dh

 

ASCII

‘0’ ‘0’

 

Function

Data

 

 

[Address code]

30h 30h (In ASCII code, ‘0’ ‘0’) fixed.

 

 

[Function code]

A code of each fixed control move.

 

 

[Data code]

A code of each fixed control data (number) and not always indicated.

[End code]

0Dh (In ASCII code, ‘

‘ ) fixed.

 

 

English

English-35

Page 36
Image 36
Mitsubishi Electronics MDT521S user manual Interface, Control command diagram