3)Control sequence

(1)The command from a computer to the LCD monitor will be sent in 600 ms.

(2)The LCD monitor will send a return command 600 ms* after it has received and encoded. If the command isn’t received correctly, the LCD monitor will not send the return command.

(3)The personal computer checks the command and confirms if the command, which has been sent, has been executed or not.

(4)This LCD monitor sends various codes other than return code. When having a control sequence by RS-232C, reject other codes from personal computers side.

*: The sending time of return command may delay depending on the condition (during changing of the input signal, etc.). Example: Turn the power ON ( ’ ’ is for ASCII code)

Sending commands

Status code from

Meaning

from the PC

LCD monitor

 

30 30 21 0D

 

Command for

’0’ ’0’ ’!’ ’ ’

 

POWER ON

 

30 30 21 0D

Command received

 

’0’ ’0’ ’!’ ’ ’

(Command echoed back)

4) Operation commands

The operation commands execute the basic operation setting of this LCD monitor.

It may not operate when changing the signal:

Operation

ASCII

HEX

POWER ON

!

21h

POWER OFF

"

22h

 

 

 

INPUT RGB 1

_r1

5Fh 72h 31h

 

 

 

INPUT RGB 2

_r2

5Fh 72h 32h

 

 

 

INPUT RGB 3

_r3

5Fh 72h 33h

 

 

 

INPUT RGB 4

_r4

5Fh 72h 34h

INPUT RGB 5

_r5

5Fh 72h 35h

INPUT VIDEO

_v1

5Fh 76h 31h

INPUT DVD/HD

_v2

5Fh 76h 32h

 

 

 

INPUT S-VIDEO*

_v3

5Fh 76h 33h

 

 

 

5) Read command

POWER OFF command should be operated over 1 minute after the power is turned on.

POWER ON command should be operated over 1 minute after

the power is turned off.

* S-VIDEO is SEPARATE only

Host computer sends the command without Data-code to monitor.

After receiving this command, the monitor returns the command with Data-code of current status to host computer. Example: When Host computer ask Power status of monitor, the status of monitor is powered-on.

 

Command from computer

 

Command from Monitor

 

Detail of command

 

 

 

 

30 30 76 50 0D

'0''0''v''P'[enter]

 

 

 

 

 

 

Ask about the power status of monitor

 

 

 

 

30 30 76 50

31 0D

'0''0''v''P''1'[enter]

 

Monitor is powered-on.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Structure of the Read-command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASCII

 

 

HEX

 

 

 

 

 

 

Function

 

Data (Receive)

 

Function

 

Data (Receive)

 

 

POWER

ON

 

 

 

vP

 

1

 

 

76 50

 

31

 

 

OFF (stand by)

 

 

 

vP

 

0

 

 

76 50

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

RGB-1 (HDMI)

 

 

 

vI

 

r1

 

76 49

 

72 31

 

 

 

RGB-2 (DVI-D)

 

 

 

vI

 

r2

 

76 49

 

72 32

 

 

 

RGB-3 (D-SUB)

 

vI

 

r3

 

76 49

 

72 33

 

 

Input

RGB-4 (BNC)

 

 

 

vI

 

r4

 

76 49

 

72 34

 

 

RGB-5 (CAT5)

 

 

 

vI

 

r5

 

76 49

 

72 35

 

 

 

 

 

 

 

 

 

 

 

 

Video

 

 

 

vI

 

v1

 

76 49

 

76 31

 

 

 

DVD/HD

 

 

 

vI

 

v2

 

76 49

 

76 32

 

 

 

S-VIDEO

 

 

 

vI

 

v3

 

76 49

 

76 33

 

 

Picture mode

HIGHBRIGHT

 

 

 

vM

 

p1

 

76 4D

 

70 31

 

 

STANDARD

 

 

 

vM

 

p2

 

76 4D

 

70 32

 

 

 

 

 

 

 

 

 

 

 

Temperature

Around

resolution

 

tc1

 

(ex.) +25

 

74 63 31

 

2B 20 32 35

 

 

Main board

1 ˚C

 

 

 

 

 

 

of internal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Around

resolution

 

 

 

 

 

 

 

 

 

 

 

monitor

 

tc2

 

(ex.) +31

 

74 63 32

 

2B 20 33 31

 

 

Power PCB

1 ˚C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

English-36