Mitsubishi Electronics MUZ-GB50VA service manual Check of outdoor thermistors

Models: MUZ-GB50VA

1 40
Download 40 pages 20.25 Kb
Page 25
Image 25

When OPERATION INDICATOR lamp flashes 6-time.

When thermistor is abnormal.

B Check of outdoor thermistors

Disconnect the connector in the outdoor electronic control P.C. board or the outdoor power board

No

 

Replace the thermistor.

(see below table), and measure the resistance of thermistor. Is the thermistor normal?

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

Reconnect the connector CN661, CN663 and CN3.

3 minutes after turning on the power supply, start EMERGENCY OPERATION.

Does the unit operate 10 minutes or more without

No

showing thermistor abnormality?

 

Yes

 

Normal

 

Replace the outdoor electronic control P.C. board.

Thermistor

Symbol

Connector, Pin No.

Board

Defrost

RT61

Between CN661 pin1 and pin2

 

Discharge temperature

RT62

Between CN661 pin3 and pin4

Outdoor electronic control P.C. board

Outdoor heat exchanger temperature

RT68

Between CN661 pin7 and pin8

 

Ambient temperature

RT65

Between CN663 pin1 and pin2

 

Fin temperature

RT64

Between CN3 pin1 and pin2

Outdoor power board