OPERATING PROCEDURE | PHOTOS |
6. Removing the compressor and | Photo 8 |
(1)Remove the top panel, cabinet and service panel. (Refer to 1.)
(2)Remove the back panel. (Refer to 1.)
(3)Remove the inverter assembly. (Refer to 2.)
(4)Recover gas from the refrigerant circuit.
NOTE: Recover gas from the pipes until the pressure gauge shows 0 kg/cm2 (0 MPa).
(5) Detach the welded part of the suction and the discharge pipe connected with compressor. (Photo 9)
(6) Remove the compressor nuts.
(7) Remove the compressor.
(8) Detach the welded part of
Welded parts of
Photo 9
R.V. coil
Welded part of the dis- charge pipe
Welded part of the suction pipe
7. Removing the reactor
(1)Remove the top panel. (Refer to 1.)
(2)Disconnect the reactor lead wire.
(3)Remove the screws of the reactor, and remove the reactor.
Photo 10
Screws of the reactor
37