PERFORMANCE CURVES

MUZ-GB50VA

The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions. Since operating conditions vary according to the areas where these units are installed. The following information has been provided to clarify the operating characteristics of the air conditioner under the conditions indicated by the performance curve.

(1)GUARANTEED VOLTAGE 207 ~ 253V, 50Hz

(2)AIR FLOW

Air flow should be set at MAX.

 

 

 

(3) MAIN READINGS

 

}

 

(1)

Indoor intake air wet-bulb temperature :

°C [WB]

 

(2)

Indoor outlet air wet-bulb temperature :

°C [WB]

Cooling

(3)

Outdoor intake air dry-bulb temperature :

°C [DB]

(4)

Total input:

W

}

 

(5)

Indoor intake air dry-bulb temperature :

°C [DB]

Heating

(6)

Outdoor intake air wet-bulb temperature :

°C [WB]

(7)

Total input :

W

 

 

Indoor air wet/dry-bulb temperature difference on the left side of the following chart shows the difference between the indoor intake air wet/dry-bulb temperature and the indoor outlet air wet/dry-bulb temperature for your reference at service.

How to measure the indoor air wet-bulb / dry-bulb temperature difference

1.Attach at least 2 sets of wet and dry-bulb thermometers to the indoor air intake as shown in the figure, and at least 2 sets of wet and dry-bulb thermometers to the indoor air outlet. The thermometers must be attached to the position where air speed is high.

2.Attach at least 2 sets of wet and dry-bulb thermometers to the outdoor air intake. Cover the thermometers to prevent direct rays of the sun.

3.Check that the air filter is cleaned.

4.Open windows and doors of room.

5.Press the EMERGENCY OPERATION switch once (twice) to start the EMERGENCY COOL (HEAT) MODE.

6.When system stabilizes after more than 15 minutes, measure temperature and take an average temperature.

7.10 minutes later, measure temperature again and check that the temperature does not change.

INDOOR UNIT

OUTDOOR UNIT

Wet and dry-bulb thermometers

8-1. Capacity and input curves

Wet and dry-bulb thermometers

temperature

(:)

air Wet-bulb

difference

Indoor

 

 

MSZ-GB50VA

8.7

8.0

7.3

6.6

5.9

5.3

MUZ-GB50VA

Rated frequency 79Hz

Indo

or

in

take

air W

et-

bulb

tem

pera

ture (

:)

Outdoor intake air Dry-bulb temperature (:)

 

 

 

)

 

 

 

(:

 

 

 

perature

 

 

-bulb

tem

 

et

 

air

W

 

 

intake

 

 

 

Indoor

 

 

 

Outdoor intake air Dry-bulb temperature (:)

9

Page 9
Image 9
Mitsubishi Electronics MUZ-GB50VA service manual Performance Curves, Indoor Unit Outdoor Unit, Capacity and input curves