Mitsubishi Electronics MUZ-GB50VA service manual Outdoor power board, CN2, CN3, CN5

Models: MUZ-GB50VA

1 40
Download 40 pages 20.25 Kb
Page 33
Image 33

3. Outdoor power board

MUZ-GB50VA

 

 

Connect to the compressor

 

 

Voltage among phases: 5V to

 

 

180V

 

325-370V DC

Connect to the earth

Output (Red)

 

 

(+)

1

CN2

 

 

 

 

(–)

3

Connect to the controller board

(+)1-5(–): Signal transmission

 

(White)

(To electronic control P.C. board)

 

 

5V DC pulse wave

 

 

 

 

 

(+)2-5(–): Zero cross signal

 

 

3-4

: Not used

 

 

(+)6-5(–): 15V

 

 

(+)7-5(–): 15V

 

 

CN3

 

 

 

Fin temperature thermistor RT64

 

 

) Signal reception (From

 

 

electronic control P.C. board)

 

 

5V DC pulse wave

 

 

CN5

 

 

 

Primary current detection

 

 

(Connect to the noise filter)

Connect to the compressor

Voltage among phases: 5V to 180V

Connect to the earth

325-370V DC Output (Red)

(+)

1

(–)3 (White)

CN2

Connect to the controller board (+)1-5(–): Signal transmission (To electronic control P.C. board)

5V DC pulse wave

(+)2-5(–): Zero cross signal 3-4 : Not used

(+)6-5(–): 15V

(+)7-5(–): 15V

CN3

Fin temperature thermistor RT64

) Signal reception (From electronic control P.C. board) 5V DC pulse wave

CN5

Primary current detection (Connect to the noise filter)

33