When unit cannot operate neither by the remote controller nor by EMERGENCY OPERATION switch. Indoor unit does not operate.

When OPERATION INDICATOR lamp flashes ON and OFF in every 0.5-second.

Outdoor unit doesn’t operate.

H How to check mis-wiring and serial signal error (when outdoor unit does not work)

Turn OFF the power supply.

Is there rated voltage in

No

the power supply?

 

Yes

Turn ON the power supply.

Check the power supply.

 

 

 

 

 

 

 

 

 

 

Is there rated voltage between

No

 

 

 

Check the wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outdoor terminal block S1 and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S2?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press EMERGENCY OPERATION switch once.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does the left lamp of OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDICATOR lamp light up?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Confirmation of the power to the indoor unit>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

Is there any mis-wiring,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is serial signal error indicated 6 minutes later?

 

No

poor contact, or wire

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disconnection of the

 

 

 

 

 

Make them correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

indoor/outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

connecting wire?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn OFF the power supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check once more if the indoor/outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

connecting wire is not mis-wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short-circuit outdoor terminal block S2 and

W1. Mis-wiring may damage indoor electronic control

 

 

 

 

 

 

 

 

 

 

S3.

 

 

 

 

 

P.C. board during the operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W1

 

 

 

 

 

Be sure to confirm the wiring is correct before the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operation starts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W3.Be sure to check this within 3 minutes after turning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON. After 3 minutes, LED blinks 6 times. Even when

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn ON the power supply.

 

 

 

 

 

the outdoor electronic control P.C. board is normal,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED blinks 6 times after 3 minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Does the LED on the outdoor electronic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Replace the outdoor electronic

 

 

 

 

 

 

 

 

 

 

 

control P.C. board repeat "3.6-second-OFF

 

 

 

 

 

control P.C. board. W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor electronic control P.C. board

 

 

and 0.8-second-ON quick blinking"? W3

 

 

 

 

(Lighted

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Parts side)

 

 

 

 

 

 

 

 

 

 

 

or not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W2 Be careful to the residual

 

 

 

LED2 LED1

 

 

 

 

 

 

 

Yes

 

 

 

 

lighted)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage of smoothing capacitor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn OFF the power supply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remove the short-circuit between

 

 

 

 

 

Is there any error of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

outdoor terminal block S2 and S3.

 

 

 

 

 

indoor/outdoor connecting wire,

 

Yes

Replace the

 

 

 

 

 

 

 

 

 

 

 

Turn ON the power supply.

 

 

 

 

 

 

 

 

 

 

Lighted Blinking

 

 

 

 

 

 

 

 

such as the damage of the wire,

 

 

 

 

 

indoor/outdoor

 

 

 

 

 

 

 

Is there amplitude of 10 to 20V DC

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

intermediate connection, poor

 

 

 

 

 

connecting wire.

 

 

 

 

 

 

 

 

 

 

 

between outdoor terminal block S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

contact to the terminal block?

 

 

 

 

 

 

 

 

 

 

A

 

 

 

and S3? <Confirmation of serial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

signal>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

· Turn OFF inverter-controlled lighting

 

 

 

 

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

equipment.

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

·Turn OFF the power supply and then turn ON again.

 

· Press EMERGENCY OPERATION

 

 

 

Is there any error of the

 

 

 

 

switch.

 

 

 

 

 

 

Is there rated voltage between

 

indoor/outdoor connecting wire,

Yes

Replace the

 

 

 

 

 

 

· Reinstall

 

 

indoor terminal block S1 and S2?

No

such as the damage of the wire,

 

 

indoor/outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Confirmation of power voltage>

intermediate connection, poor

 

 

 

 

 

 

 

 

either the

 

 

 

 

 

connecting wire.

 

 

 

 

 

 

 

 

 

 

contact to the terminal block?

 

 

 

 

 

 

 

 

unit or the

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is serial signal

 

 

 

light each

 

 

 

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

other away.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

error indicated

 

 

 

· Attach a filter

 

 

 

 

 

 

 

 

 

 

 

6 minutes later?

 

 

 

on remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

receiving

 

 

Replace the indoor electronic control P.C. board.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

section of

 

Be sure to release the failure-mode

 

 

 

 

 

 

 

 

 

 

 

 

the indoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

recall function after checking.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

unit.

 

Refer to indoor unit service manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

Page 29
Image 29
Mitsubishi Electronics MUZ-GB50VA service manual Parts side