4. Message Structures
Example
T05,I,0,230,30,1,1,0,0,B p
This text field has the following attributes:
∙Text field number is T05.
∙This field does not change value with successive tickets (IFLAG = I, increment value = 0).
∙Field begins 23 millimeters from the bottom of the print area.
∙Field begins 3 millimeters from the left edge of the print area.
∙The font appears at normal size (magnification = 1)
∙Standard font is used (1).
∙Tops of characters point to the top of the field (character rotation = 0).
∙The top of the field points to the top of the supply (rotation = 0).
∙Characters appear in Black.
Syntax Checklist
∙Make sure this record is preceded by a format header record.
∙Make sure the first parameter (field number) begins with T.
∙Make sure the row and column locations in this record are less than the supply length and width.
∙Make sure you have allowed enough space to hold all the characters in the field without running off the supply.
∙Make sure the record ends with a record separator ( p ).
∙If this is the last record in your format, place a close brace (}) at the end of the record.