4. Message Structures

 

 

ROW

One to four digits to define the row

 

location of the field on the supply. This is

 

the distance from the the guide edge zero

 

point at the bottom of the supply and the

 

bottom of the field.

 

The zero point is 1.5 mm or 0.060 inches

 

from the bottom of the supply. The bottom

 

of the supply is the edge that exits the

 

printer first.

 

 

This value is measured in tenths of

 

millimeters (TOMMS) and must be less

 

than the maximum length of the supply.

 

Values:

0-2032

COL

One to four digits to define the column

 

location of the field on the supply. This is

the distance from the guide edge zero point at the left edge of the supply and the left edge of the field.

The zero point is 1.5 mm or 0.060 inches from the left edge of the supply.

The unit of measurement is tenths of millimeters. The range must be less than the maximum width of the supply.

Values:

9425 0-508 (0 to 2 inches)

9445 0-1016 (0 to 4 inches)

9465 0-1016 (0 to 4 inches)

9474 0-1016 (0 to 4 inches)

4-11

Message Structures

Page 27
Image 27
Monarch 9400 Series manual 2032