Monessen Hearth HBDV400, HBDV300 manual Clearances To Combustibles, Mantel Clearances

Models: HBDV400 HBDV300

1 54
Download 54 pages 49.49 Kb
Page 10
Image 10
CLEARANCES

CLEARANCES

CLEARANCES TO COMBUSTIBLES

WARNING

Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.

The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.

71"Minimum

Minimum 4"

From Both

Side Walls

NOTE

All mantel shelves, regardless of depth, should be a mini-

mum of 12" from top opening of fireplace. Mantel shelf

shall not exceed 12" maximum depth at 12" minimum

height from opening.

 

 

0"–12"

Maximum Depth

12" Minimum

 

STUD

 

COMBUSTIBL

 

MATERIAL

FIREPLACE

AREA

WALL

1"

1.5"

2.5"

 

 

 

2.5"

 

 

3"

 

45°

 

 

4"

 

 

Figure 5 - Clearances

Figure 5a - Mantel clearances.

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.

10

54D5031

Page 10
Image 10
Monessen Hearth HBDV400, HBDV300 manual Clearances To Combustibles, Mantel Clearances