ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION

REMOTE WALL MOUNTED SWITCH

WARNING

A remote wall switch and up to fifteen (15) feet of 18

 

gauge wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the length provided.

Do not connect 110V to wall switch.

wall. See Figure 42. Do not extend beyond the wall switch wire

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

OPTIONAL WALL

SWITCH

ON REMOTE WALL MOUNTED SWITCH

OFF A remote wall switch and up to fifteen (15) feet of 18

RS OFF ON

WHITE

BLUE

BLACK

 

 

 

PILOT

HI

OFF

ON

TH

 

 

 

 

TP

 

 

TH/TP

GRAY

BLUE

BLACK

OPTIONAL REMOTE

RECEIVER

Do not connect 110V to wall switch. ON

RS

Figure 42 - Wiring Diagram for Wall SwitchOFF

BLACK

Figure 42 - Wiring Diagram for Wall Switch

REMOTE WALL SWITCH

Position the wall switch. Do not extend beyond the 15 feet of wire.

OPTIONAL DC REMOTE SYSTEMS

These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with the remote.

1.Plug in remote connector wire to remote receiver.

2.Connect the wire terminal from the remote receiver. This replaces the 15' wall switch connection to the switch. See Figure 42.

3.Mount remote control receiver at junction box (for your wall switch).

OPTIONAL FAN/BLOWER SYSTEMS

The junction box for the fan/blower systems has been factory installed. This system requires that 110-120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed. See Figure 43.

 

 

BLACK

 

 

GREEN

BLACK BLACK

WHITE TAN

TAN

SPEED CONTROL

 

 

OPTIONAL THERMOSTATIC SWITCH

Figure 43 - Blower Wiring Diagram

54D5031