Monessen Hearth HBDV400, HBDV300 Checking Gas Pressure And Electrical Installation, for gas leaks

Models: HBDV400 HBDV300

1 54
Download 54 pages 49.49 Kb
Page 30
Image 30
CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION

CHECKING GAS PRESSURE AND ELECTRICAL INSTALLATION

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately.

2.To ease installation, a 30" (mm) flex line with manual shut-off valve has been provided with on this appliance. Install and attach 1/2" gas line onto shut-off valve.

3.After completing gas line connection, purge air from gas line and test all gas joints from the gas meter to the fireplace for leaks. Use a solution of 50/40 water and soap or a gas sniffer.

4.To adjust flame height, turn HI/LO knob to HI to get maximum pressure to burner. Turn HI/LO knob to LO to get minimum pressure.

5.To check gas pressures at valve, turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point. Turn unit to high. See Figure 41. After taking pressure reading, be sure and turn captured screw clockwise firmly to reseal. Do not over torque. Check test points for gas leaks.

ELECTRICAL WIRING

Pressure

Test “IN”

Pressure

Test “OUT”

HI/LO

Knob Pilot Adjustment ELECTRICAL WIRING

Screw

Figure 41 - Gas Pressure Check at Gas Valve

WARNING

for gas leaks.

 

Do not use open flame to check

 

 

This fireplace will work without any electrical supply except to operate blower and electronic ignition system.

NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

CAUTION

Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

30

54D5031

Page 30
Image 30
Monessen Hearth HBDV400 Checking Gas Pressure And Electrical Installation, for gas leaks, Do not use open flame to check