Monessen Hearth HBDV300, HBDV400 manual Fireplace Installation, Gas Connection

Models: HBDV400 HBDV300

1 54
Download 54 pages 49.49 Kb
Page 29
Image 29
Figure 40 - Gas Connection

FIREPLACE INSTALLATION

WARNING

Only persons licensed to work with gas piping may make the necessary gas connections to this appliance.

CAUTION

Amanual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. See Figure 40.

NOTE : The gas line connection may be made using 1/2" rigid tubing or an approved flex connector. Since some municipalities have additional local codes it is always best to consult your local authorities and the current edition of the National Fuel Gas Code ANSI.Z223.1, NFPA54. In Canada CAN/CGA-B149 (1 or 2) Installation Code.

A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. See Figure 39.

IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the fireplace.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged burner system valves.

CAUTION

Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure 40. Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping system between fuel supply and burner system. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap collects moisture and contaminants and keeps them from going into the burner system gas controls. If sediment trap/drip leg is not installed or is installed wrong, burner system may not run properly.

CSA Design-Certified Equipment

Shutoff Valve with 1/8" NPT Tap*

Approved Flexible

Gas Line

Sediment Trap/Drip Leg

 

Natural Gas

 

From Gas Meter

Tee Joint

(4.5" W.C. to 10.5" W.C. Pressure)

Propane/LP

Pipe Nipple

From External Regulator

Cap

(11" W.C. to 13" W.C. Pressure)

 

Figure 40 - Gas Connection

54D5031

29

Page 29
Image 29
Monessen Hearth HBDV300, HBDV400 manual Fireplace Installation, Gas Connection