Motorola EP450 service manual Test Equipment, Service Aids, and Service Tools

Models: EP450

1 91
Download 91 pages 56.86 Kb
Page 20
Image 20

Chapter 3 Test Equipment, Service Aids, and Service Tools

3.1Test Equipment

Table 3-1lists test equipment required to service the EP450 Radios.

Table 3-1. Recommended Test Equipment

Motorola Part No.

Description

Characteristics

Application

 

 

 

 

R2600 series

System analyzer

This item will substitute for

Frequency/deviation meter and

 

 

items with an asterisk (*)

signal generator for wide-range

 

 

 

troubleshooting and alignment

 

 

 

 

*R1074

Fluke 87 digital multi-

True RMS metering,

Digital voltmeter is recom-

 

meter

200 kHz frequency

mended for AC/DC voltage and

 

 

counter, 32-segment bar

current measurements

 

 

graph with backlit display

 

 

 

 

 

 

Fluke 85 RF probe

500 MHz, 30 VAC max

Use with Fluke 87 digital multi-

 

 

 

meter for RF voltage measure-

 

 

 

ments.

 

 

 

 

*R1377

AC voltmeter

1 mV to 300 mV, 10 mega-

Audio voltage measurements

 

 

ohm input impedance

 

 

 

 

 

R1611

Dual channel

Two-channel, 100 MHz

Waveform measurements

 

100 MHz oscillo-

bandwidth, 200 M sample

 

 

scope (Agillent)

rate/sec, 2 MB memory/

 

 

 

channel

 

 

 

 

 

S1339

RF millivolt meter

100 V to 3V RF, 10 kHz to

RF level measurements

 

 

1 GHz frequency range

 

 

 

 

 

*R1013 or

SINAD meter or

Without RMS audio volt-

Receiver sensitivity measure-

 

 

meter or

ments

*R1370

SINAD meter with

With RMS audio voltmeter

 

 

RMS

 

 

 

 

 

 

Page 20
Image 20
Motorola EP450 Test Equipment, Service Aids, and Service Tools, Motorola Part No Description Characteristics Application