Radio Alignment Procedures: Transmitter Alignment Options

5-3

 

 

5.3.1Initial Test Equipment Control Settings

The initial test equipment control settings are listed in Table 5-1.

Table 5-1. Initial Equipment Control Settings

Service Monitor

Test Set

Power Supply

 

 

 

Monitor Mode: Power Monitor

Speaker set: A

Voltage: 13.2 Vdc

 

 

 

RF Attenuation: -70

Speaker/load:

DC on/standby:

 

Speaker

Standby

 

 

 

AM, CW, FM: FM

PTT: OFF

Volt Range: 20 V

 

 

 

Oscilloscope Source: Mod

 

Current: 20 A

Oscilloscope Horizontal: 10 mSec/Div

 

 

Oscilloscope Vertical: 2.5 kHz/Div

 

 

Oscilloscope Trigger: Auto

 

 

Monitor Image: Hi

 

 

Monitor BW: Nar

 

 

Monitor Squelch: mid CW

 

 

Monitor Volume: 1/4 CW

 

 

 

 

 

5.4Transmitter Alignment Options

Note: When checking the RF power output of the radio with a test set, always use a pad of at least 30 dB attached to the radio end of the RF cable. This will avoid an RF mismatch and ensure a stable RF reading that will not change with varying lengths of connecting cable.

5.4.1Reference Oscillator Warp

This is an important operation which affects all deviation values such as DTMF, MDC-1200 Signaling etc. The frequency will drift if not warped properly. Perform this operation prior to all other transmit tuning operations in order to minimize heating and because of the impact of warp on signaling operations.

Figure 5-3. Reference Oscillator Warp Window

HKLN4215A

December 3, 2003

Page 32