2 - 14 MC75 User Guide

Resetting the MC75
There are two reset functions, warm boot and cold boot. A warm boot re starts the MC75 by closing all running
programs. A cold boot also restarts the MC75, and also resets the clock. Data saved in flash memor y or a memory
card is not lost.
If the MC75 is not functioning properly, perform a warm boot first. If the MC75 still does not respond, perform a cold
boot.

Performing a Warm Boot

Hold down the Power button for approximately five seconds. As soon as the MC75 starts to boot r elease the
Power button.

Performing a Cold Boot

To perform a cold boot simultaneously press the Power button and the 1 and 9 keys.
Waking the MC75
The wake-up conditions define what actions wake up the mobile computer after it ha s gone into suspend mode.
The mobile computer can go into suspend mode by either pressing the Power button or automatically by Control
Panel time-out settings. These settings are configurable and the factory de fault settings are shown in Table 2-7 are
subject to change/update.
Table 2-7
Wake-up Default Settings
Condition for Wake-up Power Button Automatic Time-out
AC power is applied. No Yes
Mobile computer is inserted into a cradle. No Yes
Mobile computer is removed from a cradle. No Yes
Mobile computer is connected to a USB device. No Yes
Mobile computer is disconnected from a USB device. No Yes
A key is pressed. No Yes
The scan triggered is pressed. No Yes
The screen is touched. No No
Audio Jack No No
Audio Btn No No
Bluetooth communication Yes Yes
Incoming phone call Yes Yes