Motorola IC-T81E Adjustment Procedures, Preparation, ‘ Required Test Equipment, Connection

Models: IC-T81E IC-T81A

1 53
Download 53 pages 31.81 Kb
Page 15
Image 15

SECTION 5 ADJUSTMENT PROCEDURES

5-1 PREPARATION

REQUIRED TEST EQUIPMENT

EQUIPMENT

GRADE AND RANGE

EQUIPMENT

GRADE AND RANGE

 

 

 

 

 

 

DC power supply

Output voltage

: 13.5 V DC

DC voltmeter

Input impedance

: 50 kΩ /V DC or better

Current capacity

: 3 A or more

 

Audio generator

Frequency range

: 300–3000 Hz

 

 

 

 

 

 

 

Measuring range

: 1–10 W

Measuring range

: 1–500 mV

 

 

RF power meter

Frequency range

: 28–1500 MHz

 

 

 

 

Frequency range

: 28–1300 MHz

(terminated type)

Impedance

: 50 Ω

Standard signal

Output level

: 0.1 µV–32 mV

 

SWR

: Less than 1.2 : 1

generator (SSG)

 

 

(–127 to –17 dBm)

 

 

 

 

 

 

Frequency range

: 0.1–1500 MHz

 

 

 

Frequency counter

 

Frequency range

: DC–20 MHz

Frequency accuracy : ±1 ppm or better

Oscilloscope

Measuring range

: 0.01–20 V

 

Sensitivity

: 100 mV or better

 

 

 

 

 

 

 

 

AC millivoltmeter

Measuring range

: 10 mV–10 V

FM deviation meter

Frequency range

: 30–1500 MHz

 

 

 

Measuring range

: 0 to ±10 kHz

Attenuator

Power attenuation

: 40 or 50 dB

 

 

 

 

 

 

 

ENTERING THE ADJUSTMENT MODE q Connect a 68 kΩ terminator to the [SP] jack.

w Push and hold the [SQL] key, and then turn power ON.

Note: The frequency of wide range appears at the display using this operation.

CONNECTION

FM Deviation meter

Attenuator 40 dB or 50 dB

to the antenna connector

RF power meter 10 W/50 Ω

Frequency counter

Standard signal generator

to [SP] jack

JIG

+

68 kΩ

-

CAUTION:

DO NOT transmit while an SSG is connected to the antenna connector.

AD-92SMA

Optional SMA–BNC adaptor

1/8" (3.5 mm)

3-conductor plug

to [MIC] jack

Audio generator

AC millivoltmeter

Power supply 13.5 V / 3 A

5 - 1