Moxa Technologies user manual Setserial, Troubleshooting, Industio CP-134U Series User’s Manual

Models: CP-134U

1 87
Download 87 pages 51.18 Kb
Page 62
Image 62
Setserial

Setserial

Supported Setserial parameters are listed as below.

uart

set UART type (16450-->disable FIFO, 16550A-->enable FIFO)

close_delay

set the amount of time(in 1/100 of a second) that DTR

 

should be kept low while being closed.

closing_wait

set the amount of time (in 1/100 of a second) that the serial port should wait

 

for data to be drained while being closed, before the receiver is disabled.

spd_hi

Use

57.6kb

when the application requests 38.4kb.

spd_vhi

Use

115.2kb

when the application requests 38.4kb.

spd_normal

Use

38.4kb

when the application requests 38.4kb.

Troubleshooting

The boot time error messages and solutions are stated as clearly as possible. If you exhaust all possible solutions without solving the problem, please contact our technical support team for more help.

Error msg:

More than 4 Moxa Smartio/Industio family boards found. Fifth board and after are ignored.

Solution:

To avoid this problem, unplug the 5th, 6th, etc., boards. The Moxa driver supports a maximum of 4 boards.

Error msg:

Request_irq fail, IRQ address may conflict with another device.

Solution:

Other PCI or ISA devices are using the assigned IRQ. If you are not sure which device is causing the problem, check /proc/interrupts to find a free IRQ that can be assigned to the Moxa board.

Error msg:

Board #: C1xx Series(CAP=xxx) interrupt number invalid.

Solution:

Each port within the same multiport board shares the same IRQ. Set one IRQ (IRQ not

3-46 Industio CP-134U Series User’s Manual

Page 62
Image 62
Moxa Technologies user manual Setserial, Troubleshooting, Industio CP-134U Series User’s Manual