EDS-510A Series User’s Manual Featured Functions

3-6

Speed
Setting Description Factory Default
Auto Allows the port to use the IEEE 802.3u protocol
to negotiate with connected devices. The port and
connected devices will determine the best speed
for that connection.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the
opposing Ethernet device has trouble
auto-negotiating line speed.
Auto
FDX Flow Ctrl
This setting enables or disables the flow control capability of this port when the “port transmission
speed” setting is in “auto” mode. The final result will be determined by the “auto” process
between the EDS-510A and connected devices.
Setting Description Factory Default
Enable Enables flow control for this port when in
auto-negotiate mode.
Disable Disables flow control for this port when in
auto-negotiate mode.
Disable
MDI/MDIX
Setting Description Factory Default
Auto Allows the port to auto detect the port type of the
opposing Ethernet device and change the port
type accordingly.
MDI
MDIX
Choose the MDI or MDIX option if the opposing
Ethernet device has trouble auto-negotiating port
type.
Auto
Network
The Network configuration allows users to modify the usual TCP/IP network parameters. An
explanation of each configuration item follows.