EDS-510A Series User’s Manual Featured Functions

3-9

NOTE Changing the time zone will automatically correct the current time. You should configure the
time zone before setting the time.
Time Server IP/Name
Setting Description Factory Default
1st Time Server IP/Name IP or Domain address (e.g., 192.168.1.1 or
time.stdtime.gov.tw or time.nist.gov).
2nd Time Server IP/Name The EDS-510A will try to locate the 2nd NTP
Server if the 1st NTP Server fails to connect.
None
Time Server Query Period
Setting Description Factory Default
Query Period This parameter determines how frequently the
time is updated from the NTP server. 600 seconds
Turbo Ring DIP Switch
The EDS-510A series switches are plug-and-play, managed, redundant Ethernet switches. The
proprietary Turbo Ring protocol was developed by Moxa to provide better network reliability and
faster recovery time. Moxa Turbo Ring’s recovery time is less than 300 ms—compared to a 3 to
5-minute recovery time for commercial switches—decreasing the possible loss caused by network
failure.
A set of DIP Switches located on the EDS-510A’s outer casing can be easily used to configure the
Turbo Ring settings in only a few seconds. Some users may wish to disable the Turbo Ring DIP
Switches to avoid accidental changes to the configuration. To disable the DIP Switches, start the
user interface, and then click on Turbo Ring DIP Switch under Basic Settings. Next, select the
checkmark from the Disable the Turbo Ring DIP Switch checkbox.
Setting Description Factory Default
Enable the Turbo Ring DIP
Switch Unselect the “Disable the Turbo Ring DIP
Switch” option to enable the entire set of
Hardware DIP switches.
Disable the Turbo Ring
DIP Switch
Select the “Disable the Turbo Ring DIP
Switch” option to disable the entire set of
Hardware DIP switches.
Unselect (Turbo
Ring DIP Switch
is enabled)