Moxa Technologies EDS-510A, Moxa EtherDevice Switch user manual DIP Switch Hardware Configuration

Models: EDS-510A Moxa EtherDevice Switch

1 98
Download 98 pages 21.65 Kb
Page 25
Image 25

EDS-510A Series User’s Manual

Featured Functions

EDS-510A Series DIP Switches

1

2

3

4

------

MASTER

COUPLER

TURBO

RING

The default setting for each DIP Switch is OFF. The following table explains the effect of setting the DIP Switch to the ON position.

 

DIP Switch

 

 

Setting

 

 

Description

 

 

------

 

 

 

Serves no function (reserved for future use).

 

 

 

 

 

 

Enables the EDS-510A to be the Ring Master in a Turbo Ring

 

 

 

 

 

ON

topology, and enables the Turbo Ring break warning. If the

 

 

 

 

 

EDS-510A is the Master of this Turbo Ring, and the Turbo Ring

 

 

MASTER

 

 

 

 

 

 

 

 

is broken, the relay will form an open circuit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

Disables the EDS-510A from being the Ring Master in a Turbo

 

 

 

 

 

Ring topology, and disables the Turbo Ring break warning.

 

 

 

 

 

 

 

 

 

 

 

ON

Enables the Turbo Ring coupling function. Uses ports 7 and G1

 

 

COUPLER

 

 

of the EDS-510A to form the Ring Coupler path.

 

 

 

 

 

 

 

 

 

 

OFF

Disables the Turbo Ring coupling function.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Enables plug-and-play Turbo Ring redundancy. Ports G2 and

 

 

TURBO RING

 

 

G3 of the EDS-510A are used to form a Turbo Ring.

 

 

 

 

 

 

 

 

 

 

OFF

Disables plug-and-play Turbo Ring redundancy function.

 

 

 

 

 

 

 

 

 

 

 

 

DIP Switch Hardware Configuration

 

 

 

 

 

DIP Switch

 

 

Turbo Ring DIP

 

Description

 

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

y Turbo Ring Ports

 

 

 

 

 

 

 

 

EDS-510A: ports G2 & G3

 

 

 

 

 

 

 

 

y Coupling Ports

 

 

 

 

 

 

 

 

EDS-510A: ports 7 & G1

 

 

Enable

 

 

 

 

 

y Automatically adds the Turbo Ring and Ring Coupling

 

 

 

 

 

 

 

 

ports to the VLANs that you already specified using

 

 

 

 

 

 

 

 

the web interface.

 

 

 

 

 

OFF

 

The DIP Switch for Coupler and Master will not take

 

 

 

 

 

 

 

 

effect; you can also set up the Turbo Ring by software.

 

 

Disable

 

 

ON

 

 

The DIP Switch for Coupler and Master will not take

 

 

 

 

OFF

 

 

effect; you can also set up the Turbo Ring by software.

 

 

 

 

 

 

 

 

 

 

 

NOTE

To switch on the Master or Coupler functions of the DIP switch, you must enable the Turbo Ring

 

 

DIP Switch first.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

If you do not enable any of the EDS-510A switches to be the Ring Master, the Turbo Ring

 

 

protocol will automatically choose the EDS-510A with the smallest MAC address range to be the

 

Ring Master. If you accidentally enable more than one EDS-510A to be the Ring Master, these EDS-510A switches will auto-negotiate to determine which one will be the Ring Master.

3-10

Page 25
Image 25
Moxa Technologies EDS-510A user manual DIP Switch Hardware Configuration, DIP Switch Turbo Ring DIP Description