EDS-510A Series User’s Manual Featured Functions

3-18

only allows reading the MIB file, but does not have authorization to write.
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
No-Auth Use admin. account to access objects.
No authentication No
MD5-Auth
Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-Auth
Provide authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting Description Factory Default
Enable 8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters) No
Disable No data encryption No
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
No-Auth Use admin account or user account to
access objects. No authentication. No
MD5-Auth
Provides authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
SHA-Auth
Provides authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No
User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)
Setting Description Factory Default
Enable 8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters) No
Disable No data encryption No
Trap Settings
1st Trap Server IP/Name
Setting Description Factory Default
IP or Name Enter the IP address or name of the 1st
Trap Server used by your network. None