Chapter 6—Troubleshooting Guide

The Terminal Adapter Does Not Respond to Commands

Make sure you issue commands from the data communications software, either automatically or manually, in terminal mode. (You cannot send commands to the TA/ modem from the DOS prompt.)

Make sure you are in terminal mode in your data communications program; then type AT and press ENTER. If you get an OK response, your connections are good and the problem likely is in your phonebook entry or session settings.

If you don’t get an OK, the problem may still be in the communications software. Make sure you have done whatever is necessary in your software to make a port connection. Not all communications programs connect to the COM port automatically. Some connect when the software loads and remain connected until the program ends. Others, like MultiExpress Terminal, can disconnect without ending the program (make sure the Connect icon looks plugged in). MultiExpress Terminal also allows multiple terminals to be open, but only one can access the modem/TA at a time.

Your communications software settings may not match the physical port where the TA is connected. The serial cable may be plugged into the wrong connector—check your computer documentation to make sure. Or, you may have selected a COM port in your software other than the one where the TA/modem is connected—compare the settings in your software to the connection.

Peripheral expansion cards, such as bus mouse and sound cards, may include a serial port preconfigured as COM1 or COM2. The extra serial port, or the card itself, may use the same COM port, memory address, or interrupt request (IRQ) as your communications port. Be sure to disable any unused ports.

To look for address or IRQ conflicts if you use Windows 3.1x, select File then Run in Program Manager. Type MSD and press ENTER. Then select Mouse, COM Ports, and IRQ Status and note the addresses and IRQs that are in use. If you find an IRQ conflict, note which IRQs are not being used, then change one of the conflicting devices to use one of the unused IRQs. If you find an address conflict, change the address of one of the conflicting devices.

To change a port address or IRQ in Windows 3.1x, double-click the Control Panel icon and then the Ports icon.Click the port you want to change; then click Settings and then Advanced and select the new port address and/or interrupt. If you want to use COM3 or COM4, note that COM3 shares an IRQ with COM1, as does COM4 with COM2, so you should change their IRQs to unused ones if possible.

If you use Windows 95, right-click My Computer and select Properties. Click the Device Manager tab and then double-click Ports. Double-click the Communications Port where your modem/TA is connected. In the port’s Properties sheet, click the Resources tab to view the port’s Input/Output range and Interrupt Request. If another device is using the same address range or IRQ, it appears in the Conflicting Device List. Remove the check from Use Automatic Settings to change the port’s settings, so they do not conflict with the other device. Or, select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device, refer to the your computer’s documentation.

The serial port may be defective. If you have another serial port, install the TA on it, change the COM port setting in your software, and try again.

The TA may be defective. Call Tech Support for assistance (see Chapter 6).

MultiModemISI Hybrid Series, ISIHI-2S

113

Page 113
Image 113
Multi Tech Equipment ISIHI-2S manual Terminal Adapter Does Not Respond to Commands

ISIHI-2S specifications

The Multi Tech Equipment ISIHI-2S is a cutting-edge device designed to meet the demands of diverse industries, including manufacturing, construction, and telecommunications. This innovative piece of equipment is characterized by its versatile functionality, user-friendly interface, and robust construction, making it an ideal choice for professionals looking for reliability and efficiency.

One of the standout features of the ISIHI-2S is its advanced automation capabilities. Equipped with state-of-the-art sensors and control systems, this equipment can perform various tasks with minimal human intervention. This not only enhances productivity but also reduces the risk of errors associated with manual operation. The automation technology embedded in the ISIHI-2S allows for seamless integration into existing workflows, streamlining processes and significantly improving operational efficiency.

The ISIHI-2S also boasts a highly durable design. Constructed from high-quality materials, it is engineered to withstand harsh environments and heavy usage, ensuring longevity and reduced maintenance costs. The rugged build of the device is complemented by its lightweight nature, facilitating easy transportation and setup in various locations.

A user-friendly interface is another characteristic that sets the ISIHI-2S apart from its competitors. The intuitive control panel features a clear display, making it easy for operators to monitor performance and make adjustments as necessary. Furthermore, the device supports remote monitoring and control, allowing users to manage operations from a distance, which is particularly beneficial in large-scale projects.

In terms of technology, the ISIHI-2S incorporates advanced data analytics capabilities. Users can easily access and analyze performance data, enabling them to make informed decisions based on real-time metrics. This data-driven approach can lead to optimized operation strategies and more effective resource management.

Moreover, the versatility of the ISIHI-2S is evident in its ability to accommodate a range of attachments and accessories. This adaptability makes it suitable for various applications, from heavy lifting to intricate assembly tasks, catering to the unique needs of different industries.

In conclusion, the Multi Tech Equipment ISIHI-2S is a powerful tool that combines advanced technology, durability, and ease of use. Its automation features, robust design, user-friendly interface, and data analytics capabilities make it a preferred choice for professionals seeking reliable equipment to enhance their operational efficiency. Whether in a construction site or a manufacturing facility, the ISIHI-2S is set to revolutionize how tasks are approached and executed.