Multi Tech Equipment ISIHI-2S manual Sr=n Set S-Register, Sr? Read S-Register, Xn Connect Messages

Models: ISIHI-2S

1 186
Download 186 pages 17.87 Kb
Page 98
Image 98

Terminal Adapter

Chapter 5—TERMINAL ADAPTER AT Commands, S-Registers, Result Codes

Sr=n Set S-Register

Values: r = 0, 2–5, 7, 10, 25, 32, 50-53; n varies

Default: None

Use to set the value of an S-register, where r is the number of the S-register, and n is the value you want to set. (For more information on S-Registers, see Chapter 6, Terminal Adapter S-Registers.)

Sr? Read S-Register

Values: r = 0–5 (S1 is read only) , 7, 10, 25, 32, 50-53; n varies

Default: None

Use to read the value of an S-register, where r is the number of the S-register. (For more information on S-Registers, see Chapter 6, Terminal Adapter S-Registers.)

Vn Terse/Verbose Result Codes

Values: n = 0 or 1

Default: V1 (Verbose)

Use to control whether the TA’s result codes display as digits (terse) or as words (verbose). (Use the Q command to enable or disable the display of result codes.)

V0 Enable terse result codes.

V1 Enable verbose result codes.

Xn Connect Messages

Values: n = 0, 1, or 2

Default: X2 (Enable all messages)

Use to select which result code messages the TA sends to the computer.

X0 Enables messages OK, CONNECT, RING, NO CARRIER, and ERROR (terse result codes 0–4).

X1 Enables all messages except BUSY (terse result codes 0–5,10–14,17–19,

28, and 32). If a call is placed to a busy line, NO CARRIER displays.

X2 Enables all messages (terse result codes 0–5, 7, 10–14,17–19, 28, and 32).

ZReset to Stored Profile Values: none

Default: none

Resets TA to its current power-up profile and clears the command buffer. The result is the same as turning the TA off and on. When you type ATZ, the state of the &W command determines where default values originate. &W0 defaults come from the customized configuration in NVRAM, and &W1 defaults come from the factory default configuration in ROM. Because Z clears the command buffer, it must be the last command in a command string; normally it is issued by itself: ATZ. Note that whereas the &F0 reset command always restores the factory default profile, the Z reset command restores either the factory default or the stored profile, depending on how the &W command is set.

98

MultiModemISI Hybrid Series, ISIHI-2S

Page 98
Image 98
Multi Tech Equipment ISIHI-2S Sr=n Set S-Register, Sr? Read S-Register, Vn Terse/Verbose Result Codes, Xn Connect Messages

ISIHI-2S specifications

The Multi Tech Equipment ISIHI-2S is a cutting-edge device designed to meet the demands of diverse industries, including manufacturing, construction, and telecommunications. This innovative piece of equipment is characterized by its versatile functionality, user-friendly interface, and robust construction, making it an ideal choice for professionals looking for reliability and efficiency.

One of the standout features of the ISIHI-2S is its advanced automation capabilities. Equipped with state-of-the-art sensors and control systems, this equipment can perform various tasks with minimal human intervention. This not only enhances productivity but also reduces the risk of errors associated with manual operation. The automation technology embedded in the ISIHI-2S allows for seamless integration into existing workflows, streamlining processes and significantly improving operational efficiency.

The ISIHI-2S also boasts a highly durable design. Constructed from high-quality materials, it is engineered to withstand harsh environments and heavy usage, ensuring longevity and reduced maintenance costs. The rugged build of the device is complemented by its lightweight nature, facilitating easy transportation and setup in various locations.

A user-friendly interface is another characteristic that sets the ISIHI-2S apart from its competitors. The intuitive control panel features a clear display, making it easy for operators to monitor performance and make adjustments as necessary. Furthermore, the device supports remote monitoring and control, allowing users to manage operations from a distance, which is particularly beneficial in large-scale projects.

In terms of technology, the ISIHI-2S incorporates advanced data analytics capabilities. Users can easily access and analyze performance data, enabling them to make informed decisions based on real-time metrics. This data-driven approach can lead to optimized operation strategies and more effective resource management.

Moreover, the versatility of the ISIHI-2S is evident in its ability to accommodate a range of attachments and accessories. This adaptability makes it suitable for various applications, from heavy lifting to intricate assembly tasks, catering to the unique needs of different industries.

In conclusion, the Multi Tech Equipment ISIHI-2S is a powerful tool that combines advanced technology, durability, and ease of use. Its automation features, robust design, user-friendly interface, and data analytics capabilities make it a preferred choice for professionals seeking reliable equipment to enhance their operational efficiency. Whether in a construction site or a manufacturing facility, the ISIHI-2S is set to revolutionize how tasks are approached and executed.