ASSEMBLY INSTRUCTIONS/OPERATIONS
8FP FLOOR PLANER SERIES OPERATION AND PARTS MANUAL REV #2 (05/28/09) PAGE 22
2) Install a spacer washer next to the outside side
plate of the wide section. Next, install a flail. Follow
with a spacer washer and continue the sequence until
the section is full. FIGURE 16.
Normal installation procedure (fine finish) for
pentagonal flails
1) Install a spacer washer next to the outside side
plate of the narrow section. Next, install a flail. Follow
with a spacer washer and continue the sequence until
the section is full. FIGURE 17.
2) Install a flail next to the outside side plate of the
wide section. Next, install a spacer washer. Follow
with a flail and continue the sequence until the section
is full. FIGURE 18.
FIGURE 16
FIGURE 17
Normal installation procedure for milling flails
1) Install three spacer washers next to the outside side
plate of the narrow section. Next, install a flail. Follow
with two spacer washers and continue the sequence
until the section is full. The tungsten carbide inserts
must be installed to form a continuous planing surface.
FIGURE 19.
FIGURE 18
FIGURE 19
2) Install a flail next to the outside side plate of the
wide section. Next, install two spacer washers. Follow
with a flail and two spacer washers. Install another
milling flail followed by three spacer washers. Finally,
install the remaining flail and one spacer washer. The
tungsten carbide inserts must be installed to form the
same, continuous planing surface as in Step 1.
FIGURE 20.
3) Milling flails can also be installed on the drum
without the use of spacer washers.