Multiquip operation manual DCA-10SPX4 Setup, Circuit Breakers, Lubrication Oil, Fuel Check

Models: DCA-10SPX4

1 74
Download 74 pages 49.65 Kb
Page 25
Image 25

Circuit Breakers

To protect the generator from an overload, a 3-pole, 45 amp, main circuit breaker has been provided. In addition a single- pole, 20 amp GFCI circuit breaker is provided to protect the GFCI receptacle from overload. Additional auxiliary load circuit breakers have been provided to protect the auxiliary receptacles from overload. Make sure to switch ALL circuit breakers to the OFF position prior to starting the engine.

Lubrication Oil

Fill the engine crankcase with lubricating oil through the filler hole, but DO NOT overfill. Make sure the generator is level. and verify that the oil level is maintained between the two notches (Figure 12) on the dipstick. See Table 8 for proper selection of engine oil.

Figure 12. Engine Oil Dipstick

When checking the engine oil, be sure to check if the oil is clean. If the oil is not clean, drain the oil by removing the oil drain plug, and refill with the specified amount of oil as outlined in the KUBOTA Engine Owner's Manual.Oil should be warm before draining.

Other types of motor oils may be substituted if they meet the following requirements:

API Service Classification CC/SC

API Service Classification CC/SD

API Service Classification CC/SE

API Service Classification CC/SF

 

Table 8. Recommended Motor Oil

 

 

F

C

 

 

 

OIL: SAE

 

 

 

 

 

 

 

 

 

 

 

 

 

122

50

 

 

 

 

 

 

 

 

 

104

40

10W40

30

OIL

5W30

10W/40

15W30

10W30

10W

20W40

86

30

 

 

 

 

 

 

 

 

 

68

20

 

 

 

 

 

 

 

 

 

50

10

 

 

 

 

 

 

 

 

 

32

0

 

 

 

 

 

 

 

 

 

-14

-10

 

 

 

 

 

 

 

 

 

-4

-20

 

 

ARCTIC

 

 

 

 

 

 

-40

-40

 

 

 

 

 

 

 

 

-22

-30

 

 

 

 

 

 

 

 

 

DCA-10SPX4 — SETUP

Fuel Check

DANGER - EXPLOSION/FIRE HAZARDS

Fuel spillage on a hot engine can cause a fire or explosion. If fuel spillage occurs, wipe up the spilled fuel completely to prevent fire hazards. NEVER smoke around or near the generator.

Refilling the Fuel System

CAUTION - REFUELINGTHE GENERATOR

ONLY properly trained personel who have read and understand this section should refill the fuel tank system.

This generator has an internal fuel tank located inside the trailer frame and may also be equipped with an optional environmental fuel tank (Figure 13). ALWAYS fill the fuel tanks with clean fresh #2 diesel fuel. DO NOT fill the fuel tanks beyond their capacities.

Pay attention to the fuel tank capacity when replenishing fuel.The fuel tank cap must be closed tightly after filling. Handle fuel in a safety container. If the container does not have a spout, use a funnel. Wipe up any spilled fuel immediately.

Figure 13. Internal Fuel Tank System

DCA-10SPX4— OPERATION AND PARTS MANUAL — REV. #0 (02/17/09) — PAGE 25

Page 25
Image 25
Multiquip operation manual DCA-10SPX4 Setup, Circuit Breakers, Lubrication Oil, Fuel Check, Refilling the Fuel System

DCA-10SPX4 specifications

The Multiquip DCA-10SPX4 is a versatile and robust portable generator designed for a variety of applications, making it an excellent choice for both homeowners and professionals alike. With its compact design and powerful output, the DCA-10SPX4 is ideal for construction sites, outdoor events, and emergency backup power.

One of the standout features of the DCA-10SPX4 is its 10,000 watts of peak power output, ensuring it can handle demanding electrical loads with ease. The generator is powered by a reliable 4-cylinder engine, delivering superior performance while maintaining fuel efficiency. This combination of power and efficiency makes it suitable for both short-term use and extended periods without frequent refueling.

The DCA-10SPX4 is equipped with advanced technologies that enhance its overall reliability. It features an automatic voltage regulator (AVR) which ensures stable voltage output, protecting sensitive equipment from surges and fluctuations. This is particularly important for users who need to power electronics, tools, and other devices that require consistent voltage levels.

Another notable characteristic of the DCA-10SPX4 is its user-friendly control panel, which provides easy access to all essential functions. With multiple outlets, including 120V and 240V options, it accommodates a range of plug types, making it versatile enough for various applications. Additionally, the generator has built-in circuit breakers to prevent overloads and ensures user safety during operation.

Durability is a key aspect of the DCA-10SPX4, as it is engineered with a heavy-duty frame that can withstand rugged conditions commonly encountered on job sites. The generator also features an integrated wheel kit, allowing for easy transportation and maneuverability, which is a significant advantage when moving power equipment from one location to another.

Maintenance is simplified with the DCA-10SPX4, as it includes easy-access service points. Routine checks and oil changes can be performed quickly, ensuring the generator remains operational and prolonging its lifespan.

Overall, the Multiquip DCA-10SPX4 shines in its class due to its powerful performance, advanced technology, and user-friendly features. Whether for emergency backup, construction, or recreational use, it stands out as a reliable and efficient generator that meets the needs of diverse users.