Multiquip operation manual DCA-40SSAI Maintenance, Engine, Generator Storage

Models: DCA-40SSAI

1 140
Download 140 pages 40.94 Kb
Page 55
Image 55

DCA-40SSAI — MAINTENANCE

INSPECTION / MAINTENANCE

10 Hrs

250 Hrs

500 Hrs

1000 Hrs

DAILY

 

 

 

 

 

 

 

 

 

 

 

 

Check Engine Fluid Levels

X

 

 

 

 

 

 

 

 

 

 

Check Air Cleaner

X

 

 

 

 

 

 

 

 

 

 

Check Battery Acid Level

X

 

 

 

 

 

 

 

 

 

 

Check Fan Belt Condition

X

 

 

 

 

 

 

 

 

 

 

Check for Leaks

X

 

 

 

 

 

 

 

 

 

 

Check for Loosening of Parts

X

 

 

 

 

 

 

 

 

 

 

Replace Engine Oil and Filter *1

 

X

 

 

 

Clean Air Filter

 

X

 

 

 

 

 

 

 

 

 

Drain Bottom of Fuel Tank

 

X

 

 

ENGINE

 

 

 

 

 

Clean Unit, Inside and Outside

 

X

 

 

 

 

 

 

 

 

 

Change Fuel Filter *2

 

 

X

 

 

Clean Radiator and Check Coolant Protection

 

 

X

 

 

Level

 

 

 

 

 

 

 

 

 

 

 

Test Fuel Injection Nozzle

 

 

X

 

 

 

 

 

 

 

 

Replace Air Filter Element

 

 

 

X

 

 

 

 

 

 

 

Check all Hoses and Clamps

 

 

 

X

 

 

 

 

 

 

 

Check Valve Clearance

 

 

 

X

 

 

 

 

 

 

 

Check Injection Nozzle

 

 

X

X

 

 

 

 

 

 

 

Clean Inside of Fuel Tank

 

 

 

X

 

 

 

 

 

 

GENERATOR

Measure Insulation Resistance Over 3M ohms

 

X

 

 

 

 

 

 

 

 

*1 Replace engine oil anf filter at 100 hours, first time only. *2 Replace fuel filter at 250 Hours, first time only.

Generator Storage

For storage of the generator for over 30 days, the following is required:

zFill the fuel tank completely.

zCompletely drain the oil from the crankcase and refill with fresh oil.

zClean all external parts of the generator with a cloth.

zCover the generating set and store in a clean, dry place.

DCA-40SSAI — PARTS AND OPERATION MANUAL — FINAL COPY (07/09/01) — PAGE 55