Multiquip Reading the Output Terminal Gauges, DCA-500SSK - OUTPUTTERMINAL, W-U lug, AC Ammeter

Models: DCA-500SSK

1 114
Download 114 pages 57.54 Kb
Page 39
Image 39
Reading the Output Terminal Gauges

DCA-500SSK — OUTPUTTERMINAL

Reading the Output Terminal Gauges

The gauges and knobs on the control panel DO NOT effect the generator output. They are to help the operator observe how much power supply is produced at the UVWO legs.

To read the output at the U-W legs, place the AC Voltmeter Change-over switch to the W-U position and the AC ammeter Change-over Switch to the U or W position to read the output on the selected leg.

Figure 15. AC Voltmeter

Figure 16. AC

Change-Over Switch

Voltmeter Gauge
(Reading the W-U leg(Voltage reading on
on the output terminal

W-U lug)

Panel

 

Figure 17. AC Ammeter

Figure 18. AC

Change-Over Switch

Ammeter Gauge

(Reading the W-U leg

(Amp reading on U

on the output terminal

lug)

Panel

 