DCA-25SSIU —TROUBLESHOOTING (ENGINE)

DCA-25SSIU —TROUBLESHOOTING (ENGINE)

Practically all breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, use the tables shown for

diagnosis based on the Engine Troubleshooting (Table 14). If the problem cannot be remedied, consult our company's business office or service plant.

TABLE 14. ENGINE TROUBLESHOOTING

SYMPTOM

POSSIBLE PROBLEM

SOLUTION

 

 

 

 

No fuel?

Replenish fuel.

 

 

 

 

Air in the fuel system?

Bleed system.

 

 

 

 

Water in the fuel system?

Remove water from fuel tank.

 

 

 

 

Fuel pipe clogged?

Clean fuel pipe.

 

 

 

 

Fuel filter clogged?

Clean or change fuel filter.

 

 

 

 

Excessively high viscosity of fuel

Use the specified fuel or engine oil.

 

or engine oil at low temperature?

 

 

 

 

 

Fuel with low cetane number?

Use the specified fuel.

 

 

 

 

Fuel leak due to loose injection

Tighten nut.

 

pipe retaining nut?

 

 

Engine does not start.

 

 

Incorrect injection timing?

Adjust.

 

 

 

 

Fuel cam shaft worn?

Replace.

 

 

 

 

Injection nozzle clogged?

Clean injection nozzle.

 

 

 

 

Injection pump malfunctioning?

Repair or replace.

 

 

 

 

Seizure of crankshaft, camshaft,

Repair or replace.

 

piston, cylinder liner or bearing?

 

 

 

 

 

 

Compression leak from cylinder?

Replace head gasket, tighten cylinder head bolt, glow plug and

 

nozzle holder.

 

 

 

 

 

 

Improper valve timing?

Correct or replace timing gear.

 

 

 

 

Piston ring and liner worn?

Replace.

 

 

 

 

Excessive valve clearance?

Adjust.

 

 

 

Starter does not run.

Starter malfunctioning?

Repair or replace.

 

 

Wiring disconnected?

Connect wiring.

 

 

 

 