Multiquip ST-45HRM Engine Speed, Running, Cooling FAN, Pressure Test, Hopper Remixer Control

Models: ST-45HRM

1 132
Download 132 pages 36.47 Kb
Page 34
Image 34

ST-45 PUMP — INITIAL START-UP PROCEDURE

ENGINE SPEED

10.Turn the Operation Pump/Engine switch to the “ENGINE” position (Figure 28).

Figure 28. Operation Pump Engine

Switch

13.Make sure the Operation Pump/Engine switch is in the “ENGINE“ position (Figure 28), and that only the engine is running.

14.Turn the fan switch (Figure 30) to the “ON“ position and listen for fan to start.

Figure 30. Fan On/Off Switch

NOTE

The pump should not be cycling at this

 

time. Only the ENGINE should be

 

running.

11.While monitoring the tachometer (Figure 25), use the EngineThrottle Control to set the engine speed to 2550 RPM (maximum speed) using steps 8A-8C

12.The Accumulator Pressure Gauge (Figure 29) should read approximately 1750 pounds per square inch (psi).

Figure 29. Accumulator Pressure Gauge

COOLING FAN

This section is intended to make sure the fan is working properly. Under normal conditions the fan should be turned on when the hydraulic oil temperature begins to approach 75 degrees fahrenheit.

15.Turn the fan switch to the “OFF“ position and listen for fan to stop. If machine exceeds 170°F or to cool the machine down, turn the operation switch (Figure 28) back to the “ENGINE“ position. Run engine at high RPM with cooling fan on for 10 to 15 minutes.

PRESSURE TEST

16.The Pressure Test switch (Figure 31) is a self-diagnostic test switch, that when activated will test the pressure of the system. This switch will be discussed in the maintenance and troubleshooting section of this manual.

Figure 31. Pressure Test On/Off Switch

HOPPER REMIXER CONTROL

A.Located to the left of the Hydraulic Temperature gauge is the Hopper Remixer Control lever (Figure 32).

B.Turn the Operation Pump/Engine switch to the “ENGINE“ position (only the engine should be running).

CAUTION

If the hydraulic oil temperature exceeds 170 degrees fahrenheit, shut down the pump. DO NOT continue to operate the pump. Failure to shut down the pump will result in severe damage to the pump.

Figure 32. Hopper Remixer Control Lever

PAGE 34 — MAYCO ST-45HRM PUMP — OPERATION & PARTS MANUAL — REV. #4 (07/16/04)

Page 34
Image 34
Multiquip ST-45HRM manual Engine Speed, Running, Cooling FAN, Pressure Test, Hopper Remixer Control