CONNECTING CABLES

Connect the required cables to the appropriate connectors. Please make sure that each connector is connected to the right port with the correct orientation. Some connectors, such as the LAN connector, the external FDD connector, the power connector, the cash drawer connector, and the COM4 connector for the conversion cable have to be inserted until a click is heard. It is recommended that connectors such as the external VGA connector, the LPT port connector and the COM port connectors, be screwed into place once seated. If the COM1 port must be used, the COM1 terminator that occupies the COM1 port must be removed. However, when using the COM1 port, be sure to use devices that provide proper handshaking signals in order to keep the cash drawer control features. A serial mouse is one example of a device that does not support handshaking. Adjust the slack of each cable and close the cable cover. Use the same plastic latch key that is used when removing the cable cover, but be sure to turn it in the clockwise direction to lock the cover in place. Re-adjust the tilt angle of the screen for best viewing.

CAUTION: Before inserting or extracting the power plug, be sure to pull the outer sleeve of the plug away from the machine to release the internal latch. Failure to do this could damage the power connector. Such damage is considered to be user error, and will not be covered by the warranty.

INSTALLING CASH DRAWERS

When there is only one cash drawer installed, connect the standard cable CCBLA-180 or CCBLA-180-1 that comes with the cash drawer to the RJ11C jack next to the PS2 KB connector (be careful not to connect this cable to the Modem connector or the COM4 connector on the left).

When there are two cash drawers being installed, please purchase and use the optional cash drawer control splitter cable CCBLA-238. The CCBLA-238 has a 6 pin male connector at one end and two 8 pin male connectors at the other. The 6 pin connector should be inserted in the connector marked “CR”, found on the cabling panel of the TP6000 series. Each 8 pin connector should be inserted into the connector

TP6000 USER’S MANUAL 3 - 6

Page 18
Image 18
Mustek TP-6000 user manual Connecting Cables, Installing Cash Drawers