MINIMUM ENCLOSURE CLEARANCES

Minimum clearance to combustible construction from fireplace and vent surfaces:

Combustible framing:

-0“ to stand-offs

Non-combustible fireplace finishing:

-4“ from the sides of fi replace opening

-22 3/8 “ to the top of fi replace opening

Combustible fireplace finishing:

-0“ to rear and sides

-2” all around the vent pipe

-22 1/2 “ recessed depth

-72“ from bottom of unit to enclosure top

-72” from bottom of unit to ceiling

FIGURE 32

17

HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs to combustibles is required. Use fi restop spacer W010-1799 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles is required except for clearances in fi replace enclosures. Use fi restop spacer W500-0096 (not supplied).

!WARNING

Facing and/or finishing material must never overhang into the fireplace opening.

Do not distort or force the frame kit components.

When using a rough finish material (i.e.; stone), maintain a ¼” - ½” border from the framing

components.