24

FAN SPEED

If the appliance is equipped with a hot air circulating fan, the speed of the fan can be controlled by the remote system. The fan speed can be adjusted through six (6) speeds.

1.Use the Mode key to guide you to the fan control icon.

2.Use the Up/Down Arrow keys to turn ON/OFF or adjust the fan speed.

A single “beep” will confi rm reception of the command.

FIGURE 67

FIGURE 68

Blower off

Blower “HI” level six

CHILD PROOF FUNCTION

This function will lock the keys to avoid unsupervised operation.

1.Press the MODE and UP keys at the same time.

2.To de-activate this function, press the MODE and UP keys at the same time.

FIGURE 69

REMOTE AUXILIARY OUTLET

The auxiliary function controls the Night Light™.

1.Use the Mode Key to guide you to the AUX icon.

2.Pressing the Up Arrow Key will activate the light.

3.Pressing the Down Arrow Key will turn the light off.

A single “beep” will confi rm the reception of the command.

FIGURE 70

FIGURE 71

LOW BATTERY / MANUAL BYPASS

The life span of the remote batteries depends on various factors: qual- ity of the batteries, the number of ignitions, the number of changes to the room thermostat set point, etc.

When the transmitter batteries are low, a Battery Icon will appear on the LCD display before all battery power is lost. When the batteries are replaces this Icon will disappear.

When the receiver batteries are low, no “beep” will be emitted from the receiver when it receives an ON/OFF command. This is an alert for the receiver that there’s low battery. When the batteries are replaced the “beep” will be emitted from the receiver when the ON/OFF Key is pressed.

If the batteries of the receiver or transmitter are low, the appliance can be turned on manually by sliding the three position slider switch on the receiver to the “ON” position. This will bypass the remote control fea- ture and the appliance main burner will come on if the gas valve is in the “ON” position.

FIGURE 72

To restore button function temporarily, press the Up and Down buttons in the following sequence:

up-down-down-up-down

If no button is pressed within 2 minutes, the transmitter will return to the Child-Proof mode.

IN THE EVENT OF A POWER FAILURE

Refer to remote operation.

The receiver will emit a “beep” sound to confirm program- ming has been successful once power is restored.

FAN CONTROL MODULE

Fan Control Module (FCM) offers the added ability to control the fan speed through six (6) speeds, a remotely actuated 120V AUX outlet and a constantly powered 120V outlet. The FCM provides DC power to the receiver allowing the batteries to be used only when line power is interrupted or lost.

Note: Control module ON/OFF switch should always be in the “ON” position. If for any reason the module is turned OFF the components plugged into the module won’t have power.

FIGURE 73

MAINS VOLTAGE

SUPPLY CORD

MODULE ON/ON SWITCH

COMMUNICATION BUS (3 PIN)

AUX OUTLET PLUG

FAN OUTLET PLUG

MAINS VOLTAGE PLUG

W415-0665 / B / 02.11.08