18
W415-0665 / B / 02.11.08
2”
2”
72”
26”
8”
56”
MINIMUM
PLUS RISE*
COMBUSTIBLE NON-COMBUSTIBLE
BRICK
1”
COMBUSTIBLE
NON-
COMBUSTIBLE
0” IF NON-
COMBUSTIBLE
FINISHING IS
USED SUCH AS
BRICK AND
STONE
12 1/4” INSULATION
SLEEVE
2”
IMPORTANT:
The requires a minimum inside enclosure height
of 72”.
For temperature requirements, the enclosure space around and
above the fi replace must be left unobstructed.
* See venting section
034 789111312 5671012HEIGHTMANTELMANTEL DEPTH148

FIGURES 33

MINIMUM MANTEL AND ENCLOSURE CLEARANCES

Combustible mantel clearance can vary according to the mantel
depth. Use the graph to help evaluate the clearance needed. FIGURE 34
8” MANTEL2”4”6”14”12”10”8”TOP OF FIREPLACEOPENINGTOP OF FIREPLACENON-COMBUSTIBLE
Do NOT use the fi replace if any part has been under water.
Call a qualifi ed service technician IMMEDIATELY to have the
replace inspected for damage to the electrical circuit.
If access to the control area is necessary BEFORE INSTALLATION,
remove the access panel.
The access panel must be re-installed before operating the
unit.
It is necessary to hard wire this fi replace.
Permanently framing the fi replace with an enclosure, requires the
replace junction box to be hardwired.
This fireplace must be electrically connected and grounded in
accordance with local codes. In the absence of local codes, use
the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada
or the ANSI/NFPA 70-1996 NATIONAL ELECTRICAL CODE in the
United States.
ELECTRICAL CONNECTION

HARD WIRING CONNECTION

ELECTRICAL SCHEMATIC

FIGURE 36

FIGURE 35

RECEIVER
Receiver
12 Pin
Connector
110V OUT
Receiver Hearth Mount
OFF
ONREMOTE
TPTH
TP
TH
FCM-COM
FAN AUX OUT
Red
Black
MOTOR
Green
White
Fan Control Module (FCM)
OUT
Modulating 820
Night Lights
ON
OFF
REMOTE
Receiver Wall Mount
BLOWER