TOP OR REAR EXIT VERTICAL TERMINATION

13

TOP OR REAR EXIT VERTICAL TERMINATION

(HT) < (VT)

Simple venting configurations

Example 6:

FIGURE 16

FIGURE 17

V3

 

 

90°

 

 

 

 

 

 

 

90°

V2

 

 

 

 

 

 

 

 

H2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1

H1

90°

 

 

 

 

 

 

 

 

90°

 

 

See graph to determine the required vertical rise VT for the

 

 

 

 

 

required horizontal run HT.

 

 

V1

=5 ft

 

 

 

 

 

 

 

V

=6 ft

 

 

 

40

 

 

 

V32

=10 ft

 

 

REQUIRED

 

 

 

VT

= V1 + V2 + V3 = 5 + 6 + 10 = 21 ft

 

VERTICAL RISE

 

 

 

 

IN FEET

 

 

 

H1

=8 ft

 

 

VT

 

 

 

 

H

=2.5 ft

 

 

30

 

 

 

HR2

= H1

+ H2 = 8 + 2.5 = 10.5 ft

 

 

 

 

 

 

HO

= .03 (four 90° elbows - 90°)

 

 

 

 

 

 

 

= .03 (90 + 90 + 90 + 90 - 90) = 8.1 ft

 

 

 

 

 

 

HT

=HR + HO

= 10.5 + 8.1 = 18.6 ft

 

 

20

 

 

 

HT + VT

= 18.6 + 21 = 39.6 ft

 

 

 

 

 

 

Formula 1:

HT < VT

 

 

 

 

 

 

 

 

18.6 < 21

 

 

10

 

 

 

Formula 2:

HT + VT < 40 feet

 

 

 

 

 

 

 

39.6 < 40

 

 

3

 

 

 

Since both formulas are met, this vent configuration is

 

 

 

 

acceptable.

 

 

 

 

 

 

 

 

 

 

 

 

0

5

10

15

20

 

 

 

 

 

HORIZONTAL VENT RUN PLUS OFFSET IN FEET

HT

 

 

 

 

The shaded area within the lines represents acceptable values for HT and VT .

For vent configurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply:

Formula 1: HT < VT

Formula 2: HT + VT < 40 feet