Napoleon Fireplaces GDS26N, GDS26P Blower Installation, Night Light Replacement, Bulb Replacement

Models: GDS26P GDS26N

1 32
Download 32 pages 20.19 Kb
Page 21
Image 21
BLOWER INSTALLATION
This unit is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle. Do not cut or remove the grounding prong from this plug.
FIGURE 37a

21

BLOWER INSTALLATION

ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

 

1. Break out the blower and thermal

! WARNING

disk knock-outs from the rear panel.

Figure 37a

2. Fish the wire extension through the blower knock-out as shown and connect to the prongs on the thermodisc. Figure 37b

3.Ensure the thermodisc is touching the wall of the firebox. Secure the thermal disk assembly to the rear panel using

4of # 8 screws supplied. Figure 37b

4.Connect the variable speed switch to the jumper wire (installed in the stove) located just inside the larger knock out area. Figure 37b

5.Insert the blower assembly into the rear panel and secure using the

remaining #8 screws supplied.

 

GS67 WIRING DIAGRAM

 

6. Remove

the

VARIABLE SPEED SWITCH

 

 

THERMAL DISK

switch housing,

 

LOCATED

 

 

 

c o n n e c t

t h e

 

IN WIRE

 

 

 

variable speed

 

HOUSING

 

 

 

 

 

 

 

 

switch to the jumper

 

JUMPER WIRE (installed in stove)

 

WIRE

wire and mount the

VARIABLE

 

 

 

switch to the side

SPEED

 

 

 

EXTENSION

SWITCH

 

 

 

 

of the housing.

KNOB

 

 

 

 

 

 

 

WHITE

 

Attach and secure

 

 

 

 

 

 

 

RED

 

 

 

the variable speed

 

 

 

 

 

 

 

WHITE

BLACK

 

switch using the nut

 

 

 

 

provided. Reinstall

 

 

 

 

 

 

 

WIRE

 

the switch housing.

 

 

HARNESS

 

Install the variable

 

 

 

(included in GS67 kit)

 

s p e e d s w i t c h

 

GREEN

 

 

 

 

 

TO

 

knob.

 

BLOWER

(GROUND)

 

 

 

 

 

 

POWER

FIGURE 36

 

FIGURE 37b

 

 

 

SUPPLY

 

NIGHT LIGHTREPLACEMENT

BULB REPLACEMENT

The GDS26 comes equipped with our “Night Light™”. If in the event the lamp or lens needs to be replaced, follow these instructions.

1.Turn off all electrical supply.

2.Remove the front and door from the firebox.

3.Unscrew the lens cover making sure the washer stays in place.

Note: Do not handle the lamp (bulb) with bare fingers, protect with a clean dry cloth.

4.The lamp will pull straight out of the socket. Replace with Wolf Steel Ltd. parts only (W387-0006), as lamp and lens are special "high temperature" products .

5.Replace lens with gasket, lense covers, attach wires to quick connects and replace the door when finished.

THE FIREBOX MUST BE SEALED.

FIGURE 38 When re-assembling the light assembly, care must be taken. “Light Leakage” from above the cast doors may be noticed. The holes in the lamp housing are necessary for ventilation and must not be covered.

LENS ASSEMBLY INSTALLATION

1. Remove the door from

KEY HOLE

FIGURE 39

the firebox.

 

 

2.Run the wires up through the lens hole.

3.Align key hole with lens assembly.

4.Snap into place.

5.Replace light shields,

attach the wires and replace the door to the firebox.

LENS ASSEMBLY REPLACEMENT

1. Remove the front

FIGURE 40

door and top shield

 

f r o m t h e f i r e b o x .

 

2.Compress the retainer fins in with a screw driver while pressing firmly on the top of the light assembly.

3.Once all the retainer fins are pushed in the lens assembly will snap out of place.

W415-0607 / A / 01.18.08

Page 21
Image 21
Napoleon Fireplaces GDS26N Blower Installation, Night Light Replacement, Bulb Replacement, Lens Assembly Installation