TYPICAL VENT INSTALLATIONS

6

HORIZONTAL VENT SECTIONS: A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe in all horizontal runs to combustibles is required. Use firestop spacer W010-1313 and shield W585-0240 (supplied).

VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use firestop spacer W010- 1313 (supplied).

TYPICAL VENT INSTALLATIONS

REAR EXIT

 

TOP EXIT

FIGURE 2a

FIGURE 2b

16”

FIGURE 3a

16”

MINIMUM

 

MINIMUM

40 FT

MAXIMUM

 

 

40 FT

MAXIMUM

3 FT

MINIMUM

 

 

 

 

3 FT

MINIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20" MAXIMUM

FIGURE 3b

24" MAXIMUM

10"

MINIMUM

351/2"

29 1/8" MINIMUM

PLUS RISE*

45 1/2" MINIMUM PLUS RISE*

35 1/2"

* Refer to "Venting" Section

SPECIAL VENT INSTALLATIONS

PERISCOPE TERMINATION

Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allowable vent length is 10 ft.

FIGURE 4a

12”

 

 

FIGURE 4b

 

 

 

MINIMUM

 

 

 

12”

 

 

 

 

 

 

 

 

 

 

MINIMUM

 

24”

 

 

 

24”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MINIMUM

 

 

 

 

 

 

 

 

MINIMUM

CORNER TERMINATION

The maximum vent length for a corner installation is 20" of horizontal run, in addition to the 45° offset. In this case zero rise is acceptable. See FIGURE 5a. It is recommended to maintain a 6" rise. See FIGURE 5b.

FIGURE 5a

 

FIGURE 5b

 

 

20” MAXIMUM

 

 

6” RISE

 

 

 

 

MINIMUM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAXIMUM 10FT VENT LENGTH

W415-0607 / A / 01.18.08