MINIMUM CLEARANCES TO COMBUSTIBLES
BACK WALL
BACK WALL
SIDE WALL
SIDE WALL
Minimum clearance to combustible construction from stove and vent surfaces:
A | - | 2" |
B | - | 5" |
C | - | 2" |
-1" to bottom and sides of the vent pipe*
-2" to top of the vent pipe*
Rear Exit
-47 1/2" to ceiling from base of the unit
Top Exit
-51" to ceiling from base of the unit
*HORIZONTAL VENT SECTIONS: A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe in all horizontal runs to combustibles is required. Use firestop spacer
*VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use firestop spacer
MINIMUM MANTEL, SHELF OR CEILING CLEARANCES
REAR EXIT
TOP EXIT
FIGURE 34
COMBUSTIBLE
MANTEL, SHELF,
OR CEILING
12”
471/2”
351/2”
BRICK
0” IF
2” FINISHING IS USED SUCH AS BRICK AND STONE.
1”
29 1/8” MINIMUM
PLUS RISE *
FIGURE 35
COMBUSTIBLE
MANTEL, SHELF,
OR CEILING 2”
15 1/2”
51”
351/2”
BRICK 0” IF
2”
1”
45 1/2” MINIMUM
PLUS RISE *
5” |
The stove requires a minimum ceiling height of 47 1/2" for a rear vent. For temperature requirements, the space around and above the stove must be left unobstructed.
5”
The stove requires a minimum ceiling height of 51" for a top vent. For temperature requirements, the space around and above the stove must be left unobstructed.