MINIMUM CLEARANCES TO COMBUSTIBLES

20

MINIMUM CLEARANCES TO COMBUSTIBLES

BACK WALL

BACK WALL

SIDE WALL

SIDE WALL

Minimum clearance to combustible construction from stove and vent surfaces:

A

-

2"

B

-

5"

C

-

2"

-1" to bottom and sides of the vent pipe*

-2" to top of the vent pipe*

Rear Exit

-47 1/2" to ceiling from base of the unit

Top Exit

-51" to ceiling from base of the unit

*HORIZONTAL VENT SECTIONS: A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe in all horizontal runs to combustibles is required. Use firestop spacer W010-1313 and shield W585-0240 (supplied).

*VERTICAL VENT SECTIONS: A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use firestop spacer W010-1313 (supplied).

MINIMUM MANTEL, SHELF OR CEILING CLEARANCES

REAR EXIT

TOP EXIT

FIGURE 34

COMBUSTIBLE

MANTEL, SHELF,

OR CEILING

12”

471/2

351/2

NON-COMBUSTIBLE

BRICK

0” IF NON-COMBUSTIBLE

2” FINISHING IS USED SUCH AS BRICK AND STONE.

1”

BACK WALL 29 1/8” MINIMUM

PLUS RISE *

FIGURE 35

COMBUSTIBLE

MANTEL, SHELF,

OR CEILING 2” SIDE WALL

15 1/2

51”

351/2

NON-COMBUSTIBLE

MINIMUM MANTEL, SHELF OR CEILING CLEARANCESManual backgroundManual background BRICK 0” IF

2” NON-COMBUSTIBLE FINISHING IS USED SUCH AS BRICK AND STONE.

1”

Manual background 45 1/2” MINIMUM

PLUS RISE *

5”

The stove requires a minimum ceiling height of 47 1/2" for a rear vent. For temperature requirements, the space around and above the stove must be left unobstructed.

Manual background 5”Manual backgroundManual background

The stove requires a minimum ceiling height of 51" for a top vent. For temperature requirements, the space around and above the stove must be left unobstructed.