Chapter 5 Signal Timing
DIO 6533 User Manual 5-18 © National Instruments Corporation
Figure 5-15. Leading-Edge Mode Output Timing
Parameter Description Minimum Maximum
Input Parameters
trr* REQ pulse width 75 —
tr*r REQ inactive duration 75 —
tar ACK to next REQ 0—
Output Parameters
taa* ACK pulse width 125 —
tr*a* REQ inactive to ACK inactive 150 —
tr*do REQ inactive to new output data
(with REQ-edge latching) 050
t
rdo REQ to new output data
(with REQ-edge latching disabled) 0—
t
doa Output data valid to ACK
(with REQ-edge latching disabled) 251—
1 tdoa (min) = 25 + programmable delay All timing values are in nanoseconds.
REQ
ACK
Output Data
(REQ-edge latching)
Output Data
(REQ-edge
latching disabled)
tr*r
tr*a*
tr*do
tdoa
tar
taa*
trr*
trdo